Troubleshooting
Problem
The vacuum cleaner suddenly stops.
GB
The vacuum cleaner performance has
decreased.
The vacuum cleaner blows instead of
vacuuming (three-phase motor only).
Electrostatic current on the vacuum
cleaner.
Liquid leaks from the vacuum cleaner.
The vacuum cleaner does not start
after emptying the container.
C77
Dimension
Description
Ø 50
Junction Fitting
Ø 50
Cone
Ø 50
Curved fitting
Ø 50
Rubber suction cap 120 mm
Ø 50
Hose fitting
Ø 50
Iron flat-tip crevice nozzle
Ø 50
Oilproof rubber hose - 3 m
Ø 50
Polyurethane hose - 3 m
Ø 410
Oilproof filter
Ø 460
Fine shaving filter 50 micron
Ø 460
Fine shaving filter 100 micron
Ø 460
Fine shaving filter 300 micron
Ø 30
Level hose
Ø 560
Seal
Slush filter kit - 50 microns
Slush filter kit - 100 microns
Slush filter kit - 300 microns
Cause
Activation of the level monitoring
system.
Intervention of motor protection
devices (fuses).
The filter is clogged.
Clogged vacuum hose.
Incorrect connection to the electrical
mains.
Non existent or inefficient grounding.
The shaving container is full.
The level monitoring function did not
activate.
The level monitoring function stays
activated.
Figure 18
Function
To connect hoses or accessories
To vacuum shavings and liquids on machine
tools
To vacuum uneasily accessible areas
To vacuum shavings and dust
To connect the hose to the vacuum cleaner
To vacuum shavings, liquids and dust from
corners
To vacuum shavings and liquids
To vacuum shavings and liquids
To vacuum shavings and liquids
To vacuum fine shavings
To separate liquids from solids
Vacuum seal
Fine shaving vacuum kit
Remedy
Emptying of the liquid container.
Replace fuses and check the motor power
draw.
Replace fuses and contact an authorised
Service Centre if necessary.
Replace it.
Check the vacuum hose and clean it.
Invert two of the phase wire inside the plug.
Check all grounding, particularly the union to
the inlet.
Empty the shaving container and check the
seals.
Contact an authorized Service Centre.
Contact an authorized Service Centre.
8