Replacing The Motor; Replacing The Gears - Titan RENTSPRAY 600 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Replacing the Motor

1. Perform the Pressure Relief Procedure and unplug the
sprayer.
2. Loosen and remove the two motor cover screws. Remove
the motor cover.
3. Loosen and remove the three belly pan screws. Remove
the belly pan.
4. On the back of the motor, disconnect the wire coming
from the potentiometer and the wire coming from the
transducer. Also, disconnect the two wires coming from
the control panel board (refer to the electrical schematic in
the Parts List section of this manual).
5. Remove the four control panel mounting screws. Pull
back the control panel for access to the control panel
board.
6. At the the control panel board, disconnect the two wires
coming from the motor (refer to the electrical schematic in
the Parts List section of this manual).
7. Loosen and remove the four motor mounting screws.
8. Pull the motor out of the pump housing.
NOTE: If the motor will not dislodge from the pump
housing:
• Remove the front cover plate.
• Using a rubber mallet, carefully tap on the
front of the motor crankshaft that extends
through the slider assembly.
9. With the motor removed, inspect the gears in the pump
housing for damage or excessive wear. Replace the
gears, if necessary.
10. Install the new motor into the pump housing.
11. Secure the motor with the four motor mounting screws.
12. Reconnect the wires (refer to the electrical schematic in
the Parts List section of this manual).
13. Position the control panel on the pump housing and
secure in position using the four control panel mounting
screws.
14. Replace the belly pan. Secure with the three belly pan
screws.
15. Slide the motor cover over the motor. Secure the motor
cover with the two motor cover screws.
Motor cover
Control panel
mounting screw
Control panel
Front cover
Front cover screw
© Titan Tool Inc. All rights reserved.

Replacing the Gears

10. Remove and inspect the 2nd stage gear for damage or
11. Remove and inspect the gear and crank assembly for
12. Reassemble the pump by reversing the above steps.
NOTE: Refill the gear box in the pump housing with five
Motor
Motor
mounting
screw
Motor
cover
screw
Belly pan
Belly pan
screw
9
1. Perform the Pressure Relief Procedure and unplug the
sprayer.
2. Loosen and remove the two motor cover screws. Remove
the motor cover.
3. Loosen and remove the three belly pan screws. Remove
the belly pan.
4. On the back of the motor, disconnect the wire coming
from the potentiometer and the wire coming from the
transducer. Also, disconnect the two wires coming from
the control panel board (refer to the electrical schematic in
the Parts List section of this manual).
5. Remove the four control panel mounting screws. Pull
back the control panel for access to the control panel
board.
6. At the the control panel board, disconnect the two wires
coming from the motor (refer to the electrical schematic in
the Parts List section of this manual).
7. Loosen and remove the four motor mounting screws.
8. Pull the motor out of the pump housing.
NOTE: If the motor will not dislodge from the pump
housing:
• Remove the front cover plate.
• Using a rubber mallet, carefully tap on the
front of the motor crankshaft that extends
through the slider assembly.
9. Inspect the armature gear on the end of the motor for
damage or excessive wear. If this gear is completely worn
out, replace the entire motor.
excessive wear. Replace if necessary.
damage or excessive wear. Replace if necessary.
During reassembly, make sure the thrust washer is in
place.
ounces of Lubriplate (P/N 314-171).
Motor cover
Control panel
mounting screw
Control panel
Front cover
Front cover screw
Motor
mounting
screw
Motor
2nd stage
gear
Gear and
crankshaft
Thrust
washer
Motor
cover
screw
Belly pan
Belly pan
screw
English

Publicité

Table des Matières
loading

Table des Matières