FHP Pumps | Installation & Operation Manual
®
Listed/certified to the latest
published version of
ANSI
or its successor standard,
Cover/Grate or Suction
Fitting, screw-fastened to
Main Drain Sump
Suction Outlet
(Main Drain)
Figure 1. Number of Suction Outlets Per Pump*
*Unblockable SOFA – If acceptable by local code and Authority Having Jurisdiction (AHJ), a single unblockable
SOFA may be used. For an unblockable SOFA to qualify as an unblockable drain under the Virginia Graham
Baker Act (VGBA), the Suction Outlet Fitting Assembly (SOFA) shall be certified as unblockable, and be
designated by the manufacturer as unblockable, and the manufacturer's instructions must state the SOFA
is authorized for use as an unblockable suction outlet in accordance with ANSI/APSP/ICC-16. Certified
unblockable SOFA's must be installed in accordance with the manufacturer's instructions, the latest edition of
ANSI/PHTA/ICC-7, and applicable local code.
Section 2. Manual Usage
2.1
Introduction
This manual contains information for the proper
installation, operation, and maintenance of FHP
Pumps (FHPM models). Procedures in this manual
must be followed exactly. To obtain additional copies
of this manual, contact Zodiac Pool Systems LLC at
1.800.822.7933.
This manual also includes a "Service and
Maintenance" and "Troubleshooting" guide in
Sections 5 and 6. After installation, provide this
manual to the pool owner for reference.
/ASME
A112.19.8,
®
®
ANSI/APSP-16.
Anti-entrapment
Valves OK between pump and Tee
At Least
3 Feet
No valves between
Tee and Main Drains
Section 3. Installation
3.1
Plumbing
3.1.1 Preparation
1. Upon receipt of the pump, check the carton for
damage. Open the carton and verify all parts are
included. Check the pump for concealed damage,
such as cracks, dents, or a bent base. If you find
damage, contact the shipper or the distributor
where the pump was purchased.
3.1.2 Pump Location
To reduce the risk of fire, install pool equipment in an
area where leaves or other debris will not collect on or
around the equipment. Keep surrounding area clear of
all debris such as paper, leaves, pine needles and other
combustible materials.
1. To achieve better self-priming, Zodiac Pool
Systems LLC recommends installing the pump
within 2 feet above water level. While FHPM pumps
are certified for 10 feet of self-priming lift, when
installed more than 2 feet above water level, a
check valve is recommended on the suction line
to the pump to assist in maintaining water in the
plumbing when the pump is off.
NOTE: Better self-priming will be achieved if the pump is
installed as close as possible to the water level of the
pool.
Listed/certified to the latest
published version of
ANSI/ASME A112.19.8,
or its successor standard,
ANSI/APSP-16.
Anti-entrapment
Cover/Grate or Suction
Fitting, screw-fastened to
Main Drain Sump
Suction Outlet
(Main Drain)
Pump
WARNING