Section 5. Service and Maintenance
5.1
Clean Pump Basket
WARNING
To avoid the risk of property damage, severe personal
injury, and/or death, turn off the pump and switch off
the circuit breaker to the pump motor before servicing
the pump.
Debris in the pump basket causes restriction and
should be removed. Inspect the pump basket for
debris by looking through the clear pump lid. Clean
weekly at a minimum to maintain pump performance.
Turn off the power to the pump. If the pump is located
below the water level, close the isolation valves on the
suction and discharge sides of the pump to prevent
backflow of water.
1. Turn the lid's locking ring counter-clockwise until
'START' aligns with the ports. Carefully remove the
lid.
CAUTION
A misaligned basket will cause the lid to be improperly
seated, allowing an air leak, which could result in pump
damage.
2. Lift the basket out of the pump. Dispose of all
debris and thoroughly clean the basket, making
sure all the holes are open.
3. Replace the basket in the pump by aligning the
open section of the basket with the inlet pipe. If
aligned properly, the basket will drop easily into
place. Do not force it into place .
4. Remove the lid o-ring and remove debris around
the lid o-ring seat, as this will cause air leaks into
the system. Clean the lid o-ring and replace it.
5. Replace the lid with locking ring on the pump
housing. Align 'START' with the ports and turn the
lid's locking ring clockwise until 'LOCKED' aligns
with the ports. Hand-tighten the lid to make an air
tight seal. Do not use any tools to tighten the lid .
6. Verify that all valves have been returned to the
proper position for normal operation.
7. Open the pressure release valve on the filter, and
make sure it is clean and ready for operation.
8. Turn on the power to the pump. Once all the air
has been evacuated from the filter, close the filter
pressure release valve.
5.2
Winterizing the Pump
CAUTION
The pump must be protected when freezing
temperatures are expected. Allowing the pump to freeze
will cause severe damage and void the warranty.
Do not use antifreeze solutions in the pool, spa, or hot
tub systems! Antifreeze is highly toxic and may damage
the circulation system. The only exception to this is
Propylene Glycol. For more information see your local
pool/spa supply store or contact a qualified swimming
pool service company.
1. Drain all water from the pump, system equipment,
and piping.
2. Remove the two (2) drain plugs. Store the drain
plugs in a safe location and reinstall them when
the cold weather season is over. Do not lose the
o-rings .
3. Keep the motor covered and dry. Do not cover it
with plastic, as this will create condensation and
this moisture will damage the pump.
NOTE: To protect your pump, Zodiac Pool Systems LLC
recommends having a qualified service technician or
electrician properly disconnect the electrical wiring at
the switch or junction box. Once the power is removed,
the two (2) unions can be loosened and the pump stored
indoors. For safety, and to prevent entry of contaminants,
reinstall all conduit and terminal box covers.
4. When the system is reopened for operation, make
sure all piping, valves, wiring, and equipment
are in accordance with the manufacturer's
recommendations. Pay close attention to the filter
and electrical connections.
5. The pump must be primed prior to starting.