Télécharger Imprimer la page

Spanset RS 500 Notice D'utilisation page 21

En 1492-2 élingues rondes

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
4.4.3 Fastening to the load
– Hot, fluid loads must not be fastened.
– Fasten the SpanSet round slings or multi-leg-slings to the load so that
it cannot slip or slide during the lifting process.
– Use a suitable edge guard or cover the surface of loads with sharp
edges or rough surfaces.
– The part of the load that is to be fastened to the SpanSet round sling
or multi-leg-sling must be able to absorb the applied force.
– To save time, the SpanSet round sling or multi-leg-sling can be placed
over the crane hook
– Do not attach the choker hitch over the area with the label to avoid
damaging it.
5 Maintenance
The term maintenance encompasses cleaning, repair and disposal.
5.1 Cleaning
Clean soiled or chemically contaminated SpanSet round slings or multi-
leg-slings. The following cleaning requirements must be met:
– Cleaning in industrial washing machines possible
(Warning: no metal parts),
– Use a commercially available washing agent with a pH of < 10
(Check the pH),
– temperature setting up to 30 °C max,
– do not spin-dry the product,
– leave it to air-dry.
5.2 Repairs
Repairs may only be carried out by the manufacturer or a person commis-
sioned by the manufacturer.
Round slings are repairable under the following circumstances:
– The label is damaged and the manufacturer is known.
– An exchangeable component is damaged.
– Only the tube cover is damaged.
5.3 Disposal
(see cover).