Plumb Dot Accuracy
A free measuring distance of approximately 15'
between the floor and ceiling on a firm surface is
required. It's suggested to elevate the tool off the
ground for this operation.
1. Place the tool within 1' of the floor.
2. Turn ON the tool by pressing the power button.
3. Mark the center of the plumb point on the ceiling
(point I).
4. Rotate the tool 180° being as careful as possible
to keep the center of the laser in the exact same
location.
5. Mark the center of the top plumb point on the
ceiling (point II).
6. The distance between (points I and II) on the
ceiling is the deviation (d) of the tool. This dis-
tance should not exceed 3/64" (max.) at 30'.
For the measuring distance of 2 x 15' = 30', the
maximum allowable deviation (d) is: 30' x ±3/64"
÷ 30' = ±3/64".
NOTE: If any of the above accuracies are out of spec,
return the laser to nearest authorized MILWAUKEE
service center for recalibration.
I I
II II
15'
15'
d
d
I I
II II
MAINTENANCE
To reduce the risk of injury, always
WARNING
unplug the charger and remove the
battery pack from the charger or tool before
performing any maintenance. Never disassemble
the battery pack, charger, or tool, except as pro-
vided in these instructions. Contact a MILWAUKEE
service facility for all other repairs.
Maintain Rotary Laser
Maintain tools. If damaged, have the tool repaired
by an authorized MILWAUKEE service center before
use. Accidents may be caused by poorly maintained
tools.
ONE-KEY™
Chemical Burn Hazard.
WARNING
This device contains a
lithium button/coin cell battery. A new
or used battery can cause severe in-
ternal burns and lead to death in as
little as 2 hours if swallowed or enters the body.
Always secure the battery cover. If it does not
close securely, stop using the device, remove the
batteries, and keep it away from children. If you
think batteries may have been swallowed or en-
tered the body, seek immediate medical attention.
Internal Coin Cell Battery
An internal coin cell battery is used to facilitate full
ONE-KEY™ functionality.
To replace the coin cell battery:
1. Remove the battery pack.
2. Unscrew the fasteners on the coin cell door and
remove as one piece to open the compartment.
3. Remove the old coin cell battery, keep it away from
children, and dispose of it properly.
4. Insert the new coin cell battery (3V CR2032), fol-
low indication on the battery door.
5. Close the battery door and insert the e-clip se-
curely.
To reduce the risk of personal in-
WARNING
jury and damage, never immerse
your tool in liquid or allow a liquid to flow inside
them.
Clean dust and debris from any vents. Keep tool
clean, dry and free of oil or grease. Use only mild
soap and a damp cloth to clean, since certain clean-
ing agents and solvents are harmful to plastics and
other insulated parts. Some of these include gasoline,
turpentine, lacquer thinner, paint thinner, chlorinated
cleaning solvents, ammonia and household deter-
gents containing ammonia. Never use flammable or
combustible solvents around tools.
Cleaning the Aperture Windows
Blow off any loose particles with clean compressed
air. Carefully wipe the surface with a cotton swab
moistened with water.
Calibration and Repairs
For Calibration or Repair, return the tool, bat-
tery pack, and charger to nearest authorized
MILWAUKEE service center.
8
Cleaning