3. To turn OFF, press the Leveling Mode button
again. The Leveling Mode Indicator LED will flash
green and become solid once the level is achieved.
Entering/exiting Complete Manual Mode will re-
initialize the Bump Alarm to allow for further setup.
Manual Slope Mode
The laser plane can be manually sloped using a
paired remote/receiver. When in Manual Slope Mode,
the Leveling Mode Indicator LED will illuminate yel-
low. The laser will auto-level in one axis while sloping
in the other.
• Start the operation using the remote/receiver. See
the remote/receiver manual.
• To Exit Manual Mode from the laser, press the Level-
ing Mode button. The laser will enter Auto-Leveling
Mode and begin to self-level. The Leveling Mode
Indicator LED will turn solid green when leveling
is achieved.
Bump Alarm
Due to the laser's high leveling accuracy, the laser
is very sensitive to knocks, vibrations, and changes
in position. The Bump Alarm will be triggered if the
laser is moved from its initial location.
• The Bump Alarm will only be off while the laser
establishes a new position.
• Once the Leveling Mode is established, the Leveling
Mode Indicator LED becomes solid (green, yellow,
or red), and the Bump Alarm Indicator LED will
begin to flash white. During this time, disturbances
will not trigger an alarm but will restart the initializa-
tion timer. After 30 seconds with no adjustments or
inputs, the Bump Alarm Indicator LED will become
solid white and the Bump Alarm will be active. Any
bumps above the sensitivity limits will trigger the
alarm. The laser diode will turn off, the head will
stop rotating, the Bump Alarm Indicator LED will
flash white, and the Leveling Mode Indicator LED
will flash red. The laser will play an audible alarm.
NOTE: The laser will default to High Sensitivity. Set
up the laser on a flat and stable surface to avoid in-
terruptions in operation. If the Bump Alarm becomes
overly sensitive for environmental conditions, the
setting can be viewed and changed using a paired
remote/receiver.
Clearing the Bump Alarm (Option 1):
• Press the Leveling Mode button, and the laser will
run Auto-Leveling sequence. Additional setup may
be needed if the laser was moved from its previous
position.
Clearing the Bump Alarm (Option 2):
• If the user suspects the laser has not been signifi-
cantly disturbed, press the Rotational Speed button
to clear the warning or clear with the OK button on
paired remote/receiver and the laser head will start
spinning in its current position. Inspect the laser
plane to determine if it has been moved to determine
if re-set up is needed.
NOTE: The laser will recall previous settings that
were applied.
Sleep Mode
To conserve battery, the laser can be put into Sleep
Mode from a paired remote/receiver. In this mode,
the laser head will stop spinning, the laser diode and
the Leveling Mode Indicator LED will turn off. The
Pairing Indicator LED and Bump Alarm Indicator LED
will continue to display the current setting.
1. To turn ON Sleep Mode, select the Sleep icon from
the main menu on the remote/receiver.
2. Press the OK button to send the laser to "sleep"
mode.
3. To turn OFF Sleep Mode, press any button on the
laser or follow instructions to "wake" on a paired
remote/receiver. The laser will function with the
same settings and modes as when it entered
Sleep Mode.
Temperature Alarm
The laser monitors temperatures when the tool is
active or in Sleep Mode. If the minimum or maximum
operating temperature limits are exceeded, the
Leveling Mode Indicator LED will flash, alternating
between red>green>red; in this pattern, laser diode
will turn off, and the head will stop rotating. The laser
will automatically turn off after 5 minutes of this alarm.
Clearing the Temperature Alarm:
• Wait for the temperature to return to the normal op-
erating range stated in the "Specifications" section.
• When the tool reaches normal operating tempera-
ture, the tool will start the self-leveling process.
NOTE: The internal temperature of the tool may be
several degrees warmer than the ambient tempera-
ture. Allow 2 hours for the tool to reacclimate to the
new temperature before restarting.
Troubleshooting
• Startup Failure - If the Leveling Mode Indicator
LED flashes in an amber color immediately after
the laser is turned on, this is a result of a system
error. Return the tool to an authorized MILWAUKEE
service center.
• Leveling Error - The Leveling Indicator LED will
flash red, and the alarm will sound. Ensure that the
laser is on a level surface and the job site is clear
of obstacles. If setting up in vertical orientation,
check if it's in the correct orientation. The laser will
only work in one orientation, with the keypad fac-
ing up and parallel to the ground. Try pressing the
Leveling Mode Button to initiate Auto-Leveling. Try
power cycling the laser to clear the setting. If this
fails, return the laser to an authorized MILWAUKEE
service center.
• Bump Alarm Too Sensitive - Ensure the laser is
on a level and stable surface. Try changing to a less
sensitive setting using a paired remote/receiver.
Clear the Bump Alarm by using one of the options
from "Clearing the Bump Alarm" section. If this
fails, return the laser to an authorized MILWAUKEE
service center.
• Temperature Alarm - If the red/green Leveling
Mode Indicator LED is flashing, ensure the laser is
within the operating temperature range. Note that
the internal temperature of the tool may be 5 - 10
warmer than the ambient temperature. If stored in
excessive heat or cold, allow at least 2 hours to
acclimate to ambient temperature before turning
on the tool.
• ONE-KEY™ Lock Out - The laser will turn on briefly
but shut down after ~15 seconds. The ONE-KEY™
Indicator LED will be flashing red. This is an indica-
6