PROGRAMMING
T-SERIES
TRANSITION HUMIDITY SETTING
Adjusts how gradually your device will shift between
levels when triggered ON by the AUTO Mode's
humidity trigger. This will determine how much the
probe humidity needs to increase to step up to the
next level setting.
The higher the transition setting is, the wider the
humidity gap is between levels. The lower the
transition setting is, the smaller the humidity gap is
between levels. If this figure is set to zero, your device
will jump to your maximum level when triggered ON.
Press the up or down button to set a transition
threshold between 0% and 10%. When the sensor
humidity first reaches or crosses the humidity trigger
point, the level will increase by one (exiting OFF
Mode). Each time the threshold level is crossed, the
level will ramp up by one until it reaches the level set
in ON Mode.
EXAMPLE
In this example, your high humidity trigger is set at
70%, the OFF Mode level is 0, and the ON Mode
level is 6. If the transition threshold is set to 0%, once
the sensor humidity reaches or exceeds 70% then the
devices will trigger to run at level 7. However, if the
transition threshold is set to 2%, then the devices will
trigger to run at level 1 when it reaches or exceeds
70%. It will then step up to level 2 when reaching or
exceeding 72%, level 3 at 74%, etc. From 80% on, it
will run at level 6, the level set in ON Mode.
44