PROGRAMMING
T-SERIES
1. PORT BUTTON
Cycles through up to four
connected devices. Each device
is programmed independently, or
together when navigating to ALL.
4. UP/DOWN BUTTONS
Adjusts the value of your current
mode. The up button increases
and down button decreases the
setting. Hold both to reset values
to OFF/Default.
6. PROBE TEMPERATURE
Displays the current temperature
that the probe is detecting. Shows
"--" if no probe is plugged in.
Includes a trend indicator that
signals a rise, stability, or fall in
temperature within the last hour.
8. PROBE VPD
Displays the current VPD that
the probe is detecting (in kPa).
Shows "--" if no probe is plugged
in. Includes a trend indicator that
signals a rise, stability, or fall in
VPD within the last hour.
11. CURRENT LEVEL
Displays the connected
devices' current setting. Includes
a trend indicator that signals if the
setting is currently rising, falling,
or holding steady.
AIRTITAN T8/T8N Screen Display, and CONTROLLER 69 PRO Display
2. MODE BUTTON
Cycles through the controller's modes:
OFF, ON, AUTO (4 triggers), VPD
(2 triggers), TIMER TO ON, TIMER
TO OFF, CYCLE (ON and OFF), and
SCHEDULE (ON and OFF).
5
9. CONTROLLER MODE
Displays the controller's current mode.
Pressing the mode button cycles through
the available modes.
12. COUNTDOWN
Displays the countdown of the TIMER
TO ON, TIMER TO OFF, CYCLE,
or SCHEDULE mode activates or
deactivates the devices. TO ON shows
the amount of time left before the devices
turn on. TO OFF shows the amount of
time left before the device turn off.
9
6
8
7
14
2
1
3
3. SETTING BUTTON
Cycles through the controller's
settings: DISPLAY, CLOCK,
°F / °C, CALIB. T° / H% / kPa,
TRANS. T° / H% / kPa, BUFF. T° /
H% / kPa, and LEAF OFFSET.
5. PORTS
Displays all connected devices
as well as their current level.
10
Digits are displayed by the UIS
symbol when a device is plugged
11
into its corresponding port.
12
7. PROBE HUMIDITY
13
Displays the current humidity that
the probe is measuring. Shows
"--" if no probe is plugged in.
Includes a trend indicator that
4
signals a rise, stability, or fall in
humidity within the last hour.
10. CURRENT TIME
Displays the current time. The
internal battery sustains the clock
so it does not default to 00:00 if
power is cut off.
13. USER SETTING
Displays the value of your current
mode. Use the up or down
buttons to adjust the value.
14. ALERT ICONS
Displays alerts and statuses
of the controller, including the
controller lock, CLIMATE alert,
and TIMER alert.
27