PROGRAMMING
T-SERIES
AUTO MODE (HIGH TEMPERATURE TRIGGER)
Pressing the up or down button sets the high
temperature trigger. The devices will activate if the
probe's reading meets or exceeds this threshold.
Once triggered, the devices will gradually ramp up to
the level set in ON mode. If the probe's reading falls
below this trigger point, the devices will gradually slow
down to a stop or at the level set in OFF mode.
You may set this trigger below the low temperature trigger to create a specific range in which the
devices are active.
This is typically used with devices like air conditioners and cooling fans to help lower the
temperature when it gets too hot. For example, if you set a high temperature trigger of 90°F, then
your device will activate when the temperature reaches 90°F or higher, and turn off when it falls
below 90°F. Products shown here may still be in development.
Any of the four trigger points can activate while you are in AUTO Mode, even if you are viewing another trigger point.
Set a trigger point to OFF if not in use, by holding down the up and down button. If there is a level set in OFF Mode
other than zero the devices will run at that level when triggered to turn off.
HIGH TEMPERATURE
TRIGGER POINT
90
OFF
32
COLDER
ON
194
HOTTER
31