Adjusting flushing duration – Protronic C, Protronic T
The flushing duration can be set at one minute intervals from 1 to 10 minutes.
The flushing duration is factory-set to 5 minutes.
9.18 Press the TEST key.
9.19 Use the + and – (
• The LED in the sensor of the fitting flashes:
– 4 × short = adjustment by one stage (approx. 1 minute).
– 2 × long = End setting reached.
9.20 Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.
Adjusting flushing duration – Protronic S
The flushing duration can be set as follows:
– 10 s
– 30 s
– 60 s
– 2 min
– 3 min
– 5 min
– 7 min
– 10 min
The flushing duration is factory-set to 10 seconds.
9.21 Press the TEST key.
9.22 Use the + and – (
• The LED in the sensor of the fitting flashes:
– 4 × short = Adjust by one step.
– 2 × long = End setting reached.
9.23 Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.
) keys to adjust the flushing duration in individual steps.
) keys to adjust the flushing duration in individual steps.