Franke ZAQUA091 Notice De Montage Et De Mise En Service page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Setting the flushing interval
10.5 Press the TEST key.
• The LED flashes 4 × briefly.
• The fitting goes into Hygiene Mode.
• The LED flashes at 1 second intervals.
10.6 Use the + and – (
• The LED in the sensor flashes.
– 1 x short = Hygiene flushing off
– 2 × short = 8 h
– 3 × short = 24 h
– 4 × short = 48 h
– 5 × short = 72 h
The flushing interval is factory-set to 24 h.
Setting the flushing duration
10.7 Press the TEST key.
• The LED flashes 4 × briefly.
• The fitting goes into Hygiene Mode.
• The LED flashes at 1 second intervals.
10.8 Use the + and – (
• The LED in the sensor flashes.
– 1 x short = 10 s
– 2 x short = 30 s
– 3 x short = 60 s
– 4 x short = 2 min
The flushing duration is factory-set to 3 min.
12
) keys to adjust the flushing interval in individual steps.
) keys to adjust the flushing duration in individual steps.
– 5 x short = 3 min
– 6 x short = 5 min
– 7 x short = 7 min
– 8 x short = 10 min

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

7612982151170

Table des Matières