4.
Dimensions
5.
User Interface
A: Range
B: Time
C: Functions:
on/off: depending on fitting
D: Additional combination keys
E: LED
"Auto repeat" function
When the buttons for setting the range and the extension of flow duration are contin-
ually pressed, the command is sent again at regular intervals.
6.
Switching the Mode
The fittings operate with different baud rates. The remote control must be set on the
fitting before activation.
6.1
Press and hold the "Reset" key.
6.2
Press the "–" (
• Protronic-C, Protronic-T
The LED in the remote control flashes 2 times slowly.
• Protronic-S, Hygiene unit, Hygiene set, AQUACONTACT
The LED in the remote control flashes 4 times rapidly.
7.
Activating the Fitting for Remote Control
☞
Perform the following with the remote activation before each adjustment:
• Washbasin fittings: Trigger the valve.
• AQUACONTACT: Trigger the valve. Stop the valve.
• Urinal fittings: Place an object at the sensor for at least 5 s.
7.1
Direct the remote control (b) vertically towards the sensor (a) of the fitting at the
specified distance (d) and press a key.
☞
When the key is pressed properly, the LED (c) in the remote control flashes 2 times.
If the LED does not flash, this means either that the keys were not pressed properly
or that the battery in the remote control is empty (see
4
) key.
chapter
14.).