9.10 Press and hold the RESET key.
9.11 Additionally press the
• The LED in the sensor of the fitting flashes every second.
9.12 Release the RESET button.
9.13 Press the
• The LED in the sensor of the fitting flashes:
– 4 x short: The "Hygiene flushing" function is switched on.
– 2 × long: The "Hygiene flushing" function is switched off.
9.14 Wait 10 seconds.
• The system exits from the setting mode.
Setting the Flushing Interval
9.15 Press the TEST key.
9.16 Press the
• The LED in the sensor of the fitting flashes:
Protronic-C, Protronic-T
– 2 × long = 1 day
– 4 × short = 3 days
☞
The flushing interval is
factory-set to 3 days.
9.17 Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.
8
OFF key within 2s.
OFF key within 10 s.
ON key repeatedly until the required mode has been set.
Protronic-S
– 1 × short = 8 h
– 2 × short = 24 h
– 3 × short = 48 h
– 4 × short = 72 h
☞
The flushing interval is
factory-set to 24 h.