Franke ZAQUA091 Notice De Montage Et De Mise En Service page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Activating continual flow (thermal disinfection)
9.4
Turn the mixing lever of the fitting to the hot water limit stop (see instructions for the
fitting).
9.5
Press the
• Continual flow is started (solenoid valve opens).
Continuous flow can be prematurely terminated by pressing the
Setting the automatic safety shut-off.
When an object is continuously detected for 60s, water flow stops automatically.
9.6
Press and hold the RESET key.
9.7
Additionally press the
• The LED in the sensor of the fitting flashes.
9.8
Use the + and – (
• The LED in the sensor of the fitting flashes:
– 4 × short for each adjustment up to 60s by one step (5 s)
– 8 × short for each adjustment from 60s by one step (60 s)
– 2 x long when the respective end setting is reached
9.9
Wait 10 seconds.
• The system exits from the setting mode.
Activating/deactivating Hygiene Flushing
The "Hygiene flushing" function ensures water hygiene when the fitting is not used
for a prolonged period. After a certain adjustable interval on non-use, water flow is
activated for a selectable time.
Caution!
• When the "Hygiene Flushing" function is used, it must be ensured that the water
can flow away properly.
• When the "Hygiene flushing" function is to be used for both the hot and cold water
lines, the mixer lever of the fitting should be in the mixed-water position.
This function is not available for products manufactured before 1 May, 2002. When
the respective keys are pressed, the LED in the sensor of the fitting does not flash.
Important!
Protronic-C, Protronic-T: When the "Hygiene flushing" function is active, this state is
indicated by an LED within 3 minutes after the voltage supply is interrupted and
reconnected for object detection.
The factory default setting for "Hygiene Flushing" is deactivated.
ON key.
OFF key within 2s.
) keys to adjust the switch-off time in individual steps.
ON key again.
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

7612982151170

Table des Matières