Activating continual flow (thermal disinfection)
9.4
Turn the mixing lever of the fitting to the hot water limit stop (see instructions for the
fitting).
9.5
Press the
• Continual flow is started (solenoid valve opens).
☞
Continuous flow can be prematurely terminated by pressing the
Setting the automatic safety shut-off.
When an object is continuously detected for 60s, water flow stops automatically.
9.6
Press and hold the RESET key.
9.7
Additionally press the
• The LED in the sensor of the fitting flashes.
9.8
Use the + and – (
• The LED in the sensor of the fitting flashes:
– 4 × short for each adjustment up to 60s by one step (5 s)
– 8 × short for each adjustment from 60s by one step (60 s)
– 2 x long when the respective end setting is reached
9.9
Wait 10 seconds.
• The system exits from the setting mode.
Activating/deactivating Hygiene Flushing
The "Hygiene flushing" function ensures water hygiene when the fitting is not used
for a prolonged period. After a certain adjustable interval on non-use, water flow is
activated for a selectable time.
Caution!
• When the "Hygiene Flushing" function is used, it must be ensured that the water
can flow away properly.
• When the "Hygiene flushing" function is to be used for both the hot and cold water
lines, the mixer lever of the fitting should be in the mixed-water position.
☞
This function is not available for products manufactured before 1 May, 2002. When
the respective keys are pressed, the LED in the sensor of the fitting does not flash.
☞
Important!
Protronic-C, Protronic-T: When the "Hygiene flushing" function is active, this state is
indicated by an LED within 3 minutes after the voltage supply is interrupted and
reconnected for object detection.
☞
The factory default setting for "Hygiene Flushing" is deactivated.
ON key.
OFF key within 2s.
) keys to adjust the switch-off time in individual steps.
ON key again.
7