10.2 Injection unit (optional)
Fault
No injection
Too much/too little
spray mist
Too little spray mist
No spray mist
Tab. 15
Troubleshooting for the injection unit
BAL.0030 • 2022-03-31
Cause
• Check the fill level
• Compressed air supply/hose
connections interrupted
• Mechanically operated injection
valve Y4 does not switch
• Anti-spatter fluid is empty
• Metering quantity incorrectly
adjusted
• Injection time too short
• Operating pressure too low
• Operating pressure too low
10 Troubleshooting
Troubleshooting
• Top up the anti-spatter fluid
• Check all supply lines leading to the cylinder and
threaded fittings
• Replace mechanically operated injection valve Y4
• Replace or refill bottle
• Adjust the throttling screw
• Check injection time (torch dwell time in injection
unit)
• Check the operating pressure
• Check the operating pressure