OPERATING INSTRUCTIONS
INTERIOR LIGHT
The interior light will default to turning on and off
when the door is opened or closed.
Press the light button once to turn the light off while
the door is open. The light will resume default
functioning when the door is closed.
There are four light mode settings:
• L1: Light will turn on and off when the door is
opened and closed.
• L2: Light will remain on indefinitely at 100%
illumination.
• L3: Light will remain on for 120 minutes at 100%
illumination and then resume default operation.
• L4: Gallery Mode
When door is closed the control panel display
will turn off. Cabinet lights will remain on 100%
illumination for 120 minutes, before dimming to
50% and remain on indefinitely.
INTERIOR LIGHT COLOR
The interior light can be set to either white or blue.
• Press and hold the light button for 3 seconds
until the interior light color symbol flashes.
• Press the light button to toggle between a white
or blue light.
The interior light color setting indicator light will
flash 5 times to confirm the change.
FUNCTION INSTRUCTION
The default temperature setting for the upper
chamber is 42°F (6°C) and the lower chamber is
54°F (12°C). The default temperature scale is °F.
To switch the display between °F and °C, press
and hold the increase and decrease buttons
simultaneously for approximately 3-5 seconds.
The temperature for the upper chamber can be set
as low as 34°F (1°C) or as high as 50°F (10°C). The
temperature for the lower chamber can be set as
low as 50°F (10°C) or as high as 64°F (18°C).
Actual temperature inside the appliance can vary
based on ambient temperature, how often the
door is opened and how many warm bottles have
recently been added to the appliance.
If the appliance loses power, the control panel
will remember the set temperature. Once power
is restore, the appliance will return to normal
functioning automatically.
If the inner cabinet temperature is higher than
73°F (23°C) for one hour, the error code "HI" will
show on the display, the alarm indicator light will
illuminate and an alarm will sound.
If the inner cabinet temperature is lower than 28°F
(-2°C) the error code "LO" will show on the display,
the alarm indicator light will illuminate and an
alarm will sound.
If the inner cabinet temperature remains at 28°F
(-2°C) for more than 30 minutes, the error code
"CL" will show on the display, the alarm indicator
light will illuminate and an alarm will sound. The
appliance will stop functioning to prevent the
contents from freezing.
Demo Mode: Demo mode is only intended to be
used on the sales floor. It can be used to show
how the appliance will look while running without
engaging the compressor or the cooling function.
The fan will run on low speed but all alarms and
beeping will be disabled.