Filters saturation INDICATOR:
The hood warns the user at regular intervals that the filters
have to be cleaned/replaced.
With the T1 key lit and the +T2 key flashing, it is necessary to
replace the Grease Filter
With the T1 key lit and the +T3 key flashing, it is necessary to
replace the Carbon Filter
With the T5 and +T6 keys flashing, it is necessary to replace
the HEPA Filter
Note: the indication of filters saturation is visible only within
the first 10 seconds of turning on the hood.
RESET Filters saturation Alarm:
Only if the Filters saturation alarm is displayed:
pressing keys T1+T2 simultaneously for about 3 seconds will
reset the Grease Filter saturation alarm.
pressing keys T1+T3 simultaneously for about 3 seconds will
reset the Carbon Filter saturation alarm.
At any time, even if the filters saturation alarm is not
displayed, pressing keys T5+T6 simultaneously for about 3
seconds will reset the HEPA Filter saturation alarm.
ACTIVATE / DISABLE the Filters counter.
With motor (A) and (B) in OFF, pressing keys T2+T3
simultaneously will open the Filters saturation indicator
management menu.
From this menu:
− Pressing the T2 key activates / disables the Grease Filter
indicator.
Note: The Grease Filter is ACTIVATED as the default setting.
− Pressing the T3 key activates / disables the Carbon Filter
indicator.
Note: The Carbon Filter is DISABLED as the default setting.
Pressing keys T2+T3 again will close the menu and save the
changes made.
Maintenance
Cleaning
Clean using ONLY a cloth dampened with neutral liquid
DO
NOT
detergent.
INSTRUMENTS. Do not use abrasive products. DO NOT USE
ALCOHOL !
Grease filter
Fig. F02
The grease filter must be cleaned once a month using non
aggressive detergents, either by hand or in the dishwasher,
which must be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolor
slightly, but this does not affect its filtering capacity.
Charcoal filter (filter version only)
Fig. F01
Circular charcoal filter
Apply one on each side as cover to both the shield grids of the
motor impeller, then turn clockwise.
For the disassembly, turn counter-clockwise.
The saturation of the charcoal filter occurs after more or less
CLEAN
WITH
TOOLS
prolonged use, depending on the type of cooking and the
regularity of cleaning of the grease filter.
In any case it is necessary to replace the cartridge at least
every four months.
The charcoal filter may NOT be washed or regenerated.
HEPA Filter
The HEPA filter cannot be washed or cleaned.
A signal will indicate the moment when the filter will have to be
replaced.
ATTENTION!!! The HEPA filter must be replaced every time
it is signalled and anyway at least every 12 Months.
The HEPA filter lifetime depends on the characteristics of the
operation environment of the appliance. Under normal
conditions (domestic environments) the filter lifetime is about
8-10 months, and an electronic device indicates the moment
when it must be serviced according to the volume of air
effectively purified
Frequent use anticipates saturation and reduces lifetime.
Highly damp and/or dusty environments anticipate the filter
saturation and efficiency.
The Hepa filter lifetime depends on the conditions of use.
Fig. F03
Replacing lamps
The hood is equipped with a lighting system based on LED
technology.
The LEDs guarantee an optimum lighting, a duration up to 10
times longer than the traditional lamps and allow to save 90%
electrical energy.
The lighting system cannot be replaced by the user, contact
Customer Service in case of malfunction.