Usually the relay will be activated in case of an alarm, i.e. in case of an error the relay will be deactivated
and an error will be signalled. In case of inverted function, the relay is activated if there is no error.
Factory setting: No
Delete registered channel
Possibility to delete a registered ice detection channel.
It is only possible to delete a registered channel (e.g. when changing the channel number) by resetting
the 1873 to its factory settings or by using this menu item and specifying the channel number.
Time control
Possibility to activate the use of a week program for the respective zone.
Factory setting: No
Follow up time
Adjustment of the follow up time. This is the time during which the heating will continue to be active even
if the regular heating time has run out and the moisture value is again below the defined moisture thres-
hold.
Factory setting: 0 min
Base temperature
Adjustment of the target value for the ground temperature in the base temperature mode. As soon as the
outside temperature falls below the defined upper temperature limit, the heating is switched on in order to
keep the ground temperature on the defined base temperature level.
Factory setting: -5 °C
Zone number
Definition to which zone this ice detection channel belongs. If the value is 0, the channel will not be as-
signed to any zone.
Factory setting: 0
Heating performance
Adjustment of the heating performance for mathematical assessment of the used heating energy (opera-
ting hour counter multiplied by heating performance equals heating energy).
Factory setting: 0 W