10.3 Safety warnings
er1: Maximum temperature limit: The machine has an internal
device that does not allow the temperature to exceed 220ºC
(428ºF). If this happens, the message er1 will appear on the
screen. If the error persists, you must contact official technical
service to repair the malfunction.
er2: Slow glue heating: When this error appears, it is becau-
se the machine is heating slower than is expected, normally
due to an element in the machine having broken. If this error
persists, you must contact official technical service to repair
the malfunction.
er3: No temperature reading: This error appears when the
machine cannot read the glue temperature because the probe is
disconnected or has stopped working. If this error persists, you
must contact official technical service to repair the malfunction.
A01: This warning appears once the machine has been ope-
rating continuously for 50 hours. Figures A and B in (Fig. 17)
indicate the need for a general cleaning of the machine and
maintenance of the moving parts.
A02: This warning appears once the machine has been ope-
rating continuously for 100 hours. Figures C and D in (Fig. 17)
indicate the cleanliness of the glue tank.
A03: This shows the time during which the machine has been
operating in hours and minutes. To see the time, leave the
machine in OFF and press one of the two pushbuttons C or
D (Fig. 16-3). The minutes will be shown on screen E and the
hours on screen F (Fig. 16-3).
Automatic stop: The machine will automatically stop once
it has been operating for 2 hours. If you would like to keep
working, you simply need to start up the machine again.
Eliminate warnings: To eliminate all the safety warnings, you
just need to press main switch A (Fig. 16-3) once.
11. STATIONARY USE
Your portable gluing machine can be turned into a tabletop
hot gluing machine if you fix it onto table MEB250 (optional
accessory).
Fixing the PEB250 onto the table simply involves placing it
inside this and fastening it in place with the 3 screws that
come with it.
The MEB250 table has an auxiliary pressure roller; support
guides for the board as it enters and exits; a rear support guide
which can be extended up to 500 mm and a detachable press
for the banding of straight pieces.
With this you can practically and simply band straight pieces
and you can also band small pieces, which are round or shaped,
on top of the table
With the help of screen C (Fig, 16c), you can also convert your
portable gluing machine into a stationary machine if you make
your own auxiliary table.
PEB250 EVOLUTION - 35

Publicité

loading