CFX
Connecting to an AC power supply (e.g. in the home or office)
D
DANGER! Electrocution hazard
• Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
• If you are operating your cooling box on board a boat from an
AC power supply, you must install a residual current circuit breaker
between the AC power supply and the cooling box.
Seek advice from a trained technician.
The cooling box has an integrated multi-voltage power supply with priority circuit for
connecting to an AC voltage source. The priority circuit automatically switches the
cooling box to AC operation, if the device is connected to an AC power supply,
even if the DC connection cable is still attached.
When switching between the AC power supply and the battery supply, the red LED
may light up briefly.
1. Plug the AC connection cable (fig. 1 3, page 3) into the AC voltage socket of
the cooling box (fig. 4 1, page 4).
2. Connect the connection cable to the AC power outlet.
7.4
Using the battery monitor
The device is equipped with a multi-level battery monitor that protects your vehicle
battery against excessive discharging when the device is connected to the on-board
DC supply.
If the cooling box is operated when the vehicle ignition is switched off, the cooling
box switches off automatically as soon as the supply voltage falls below a set level.
The cooling box will switch back on once the battery has been recharged to the
restart voltage level.
A
NOTICE! Damage hazard
When switched off by the battery monitor, the battery will no longer be
fully charged. Avoid starting repeatedly or operating current consumers
without longer charging phases. Ensure that the battery is recharged.