suMMER sTop
after cleaning the hearth, chimney and hood, totally eliminating the ash and other eventual residues, close all the doors of the hearth and
the relevant registers; in case you disconnect the appliance from the chimney you must close its openings in order to let work others possible
appliances connected to the same flue.
We suggest performing tHe cLeaning operation of tHe fLue at Least once per year; verifying in tHe meantime tHe actuaL
status of tHe rope seaLs, WHicH cannot ensure tHe good operation of tHe eQuipment if tHey are not in good condition
and are not making a good seaL! in tHis case tHe seaLs must be repLaced.
in presence of dampness in tHe room WHere tHe product Has been pLaced, We advise you to put absorbent saLts into
tHe HeartH.
if you Want to keep for Long tHe aestHetic Look of tHe cooker it is important to protect its internaL WaLLs
in roW cast iron WitH neutraL vaseLine.
RouTINE MAINTENANCE pERfoRMED by quAlIfIED TEChNICIANs
RouTINE MAINTENANCE MusT bE pERfoRMED AT lEAsT oNCE A yEAR.
using Wood as soLid fueL, tHe generator reQuires annuaL routine maintenance, WHicH must be performed by a
quAlIfIED TEChNICIAN, usINg oNly oRIgINAl spARE pARTs.
faiLure to compLy can jeopardise tHe safety of tHe appLiance and make tHe Warranty nuLL and void.
respecting the frequencies of cleaning reserved for the user described in the use and maintenance manual, the generator is guaranteed
correct combustion over time, preventing any anomalies and/or malfunctioning that could require more interventions of the technician.
reQuests for routine maintenance are not contempLated in tHe product Warranty.
gAsKETs
the gaskets guarantee the tightness of the product and its consequent good functioning.
tHey must be controLLed periodicaLLy. tHey must be repLaced immediateLy if tHey are Worn or damaged.
tHese operations must be carried out by a QuaLified tecHnician.
CoNNECTIoN To ThE fluE
vacuum and cLean tHe pipe tHat Leads to tHe fLue yearLy or any time tHat it is necessary. if tHere are HorizontaL tracts,
tHe residue must be removed before it can prevent tHe passage of tHe fumes.
fAN - ClEANINg AND MAINTENANCE
always follow the instructions in maximum safety conditions!
• make sure that the power cable is unplugged since the fan could be to start.
• that the generator is cold in its entirety.
• the ashes are completely cold.
• ensure an effective exchange of air in the room during the cleaning of the product.
a poor cleaning is detrimental to the proper functioning and safety!
MAINTENANCE
for correct operation, the generator must undergo routine maintenance by a qualified technician at least once a year.
the routine checks and maintenance operations must always be performed by qualified trained technicians in accordance with the applicable
regulations in force and with the instructions provided in this use and maintenance manual.
wARNINg if tHe poWer suppLy cabLe is damage d, it must be repLace d by tHe after-saLes serv ice or by a simiLarLy
QuaLified person, so as to avoid aLL risks