Installation instructions
Installation and repair of the
gas remote switch are only to
be carried out by an expert.
When using control panels
which are specific to the vehicle
or manufacturer, the electrical
connection must be effected in
accordance with Truma interface
specifications.
Installation of GS 8 and
GS 10 on single-cylinder
gas systems
Fig. A1: Assemble solenoid
valve (1) between gas hose (2)
and gas line (3).
10
Installation of GSE on
single-cylinder gas
systems
Fig. A2: Fit solenoid valve (1)
between pressure regulator (8)
and gas hose (2).
Installation of GS 8 and
GS 10 on two-cylinder
gas systems
Fig. B, Truma Duomatic Plus /
Duomatic L Plus:
Assemble solenoid valve (1)
between gas hose (2) and gas
line (3).
Fig. C, D, E, wall-mounted
regulator (Truma Triomatic,
DuoControl, SecuMotion):
Unscrew gas line (3) from gas
pressure regulator (5). Fit sole-
noid valve (1) to gas line (3) and
connect gas pressure regulator
(5) to solenoid valve (1) (shorten
gas pipe with a suitable pipe
cutter if necessary – do not use
a saw).
The gas pipe must be
de-burred after cutting,
and must still have the full pipe
diameter.
Electrical connection
Route connecting cable (6) of
the solenoid valve with insulating
tape parallel to the gas pipe and
into the interior, to the intended
location of the control panel (9).
Extend if necessary, using a
3 x 0.75 mm² cable.