Installation instructions
Installation and repair of the
gas remote switch are only to
be carried out by an expert.
When using control panels
which are specific to the vehicle
or manufacturer, the electrical
connection must be effected in
accordance with Truma inter-
face specifications. The installer
(manufacturer) is responsible for
providing operating instructions
for the user (and the printing of
the control panel).
10
Installation of GSE on sin-
gle-cylinder gas systems
Fig. A
Fit solenoid valve (1) between gas
pressure regulation system (8)
and gas hose (2). Connection 1/4"
anticlockwise outer thread.
Fitting GS 8 and GS 10 to
the one-cylinder or two-
cylinder gas system
Olive screw connection, 8 mm
or 10 mm.
Fig. B + C
The solenoid valve (1) is fitted
between the gas hose (2) and
the gas line (3 – fig. B) or be-
tween the gas line (3) and the
gas pressure regulating system
(5 – fig. C). Shorten gas pipe
with a suitable pipe cutter if nec-
essary – do not use a saw.
The gas pipe must be
de-burred after cutting,
and must still have the full pipe
diameter.
Electrical connection
Route connecting cable (6) of
the solenoid valve with insu-
lating tape parallel to the gas
pipe and into the interior, to the
intended location of the control
panel (9). Extend if necessary,
using a 3 x 0.75 mm² cable.
The connection of
the extension is not
to take place in the cylinder
compartment! For the cylinder
compartment opening (figures
page 2: 7) use a rubber sleeve or
body sealing compound. Provide
leadthrough at least 50 cm
above the bottom of the cylinder
box.