2.4
Specifications
General information
Dimensions
Tilt height
Minimum room height for anode replacement
Connections
Connection size, DHW
Connection size, cold water
Connection size, circulation
Inner diameter, test point, cylinder temperature sensor
Dry weight (excluding packaging)
Total weight when filled
Cylinder capacity
Useful capacity (overall)
1)
Usable DHW volume
with DHW outlet temperature
45 °C
40 °C
Standby heat loss according to DIN EN 12897
Maximum flow rate, cold water inlet
Maximum DHW temperature
Maximum operating pressure, potable water
Highest design pressure (cold water)
Maximum DHW test pressure
Heat exchanger
Content
Surface area
Performance factor N
according to DIN 4708
L
Continuous output (at 80 °C flow temperature, 45 °C DHW
outlet temperature and 10 °C cold water temperature)
Heat-up time at rated output
Max. heating with electric heating, only with W 200-5 EP
Maximum heating water temperature
Maximum heating water operating pressure
Connection size, heating water
Pressure drop diagram
Table 4 Dimensions and specifications (
1) Without recharging; set cylinder temperature 60 °C
2) Mixed water at draw-off point (at 10 cold water temperature) °C
3) Distribution losses outside the DHW cylinder are not taken into account.
4) The performance factor N
=1 according to DIN 4708 for 3.5 persons, standard bath tub and kitchen sink. Temperatures: cylinder 60 °C, outlet 45 °C and cold water 10.
L
Measured at max. heat output. If the heat output is reduced, N
5) In the case of heat sources with a higher heat output, limit to the stated value.
W 120-5 P | W 160-5 P | W 200-5 P | W 200-5 EP – 6 720 821 084 (2022/03)
Unit
W 120-5 P
A
mm
1200
mm
1390
DN
R1"
DN
R1"
DN
R¾ "
mm
19
kg
67
kg
187
l
115
2)
:
l
163
l
190
3)
kWh/24 h
0.88
l/min
12
°C
95
bar
10
(positive)
bar
7.8
(positive)
bar
10
(positive)
l
4.8
2
m
0.7
4)
NL
1.4
kW
25
l/min
10.2
min
19
5)
kW
-
°C
160
bar
16
(positive)
DN
R1"
Fig. 1, page 59 and Fig. 3, page 60)
becomes smaller. °C
L
W 120-5 P
W 160-5 P
W 160-5 P
B
A
B
 Fig. 1, page 59
1160
1450
1410
1370
1650
1650
 Tab. 6, page 34
R1"
R1"
R1"
R1"
R1"
R1"
R¾ "
R¾ "
R¾ "
19
19
19
64
77
74
184
237
234
115
156
156
163
217
217
190
253
253
1.0
0.92
1.1
12
16
16
95
95
95
10
10
10
7.8
7.8
7.8
10
10
10
4.8
6.0
6.0
0.7
0.9
0.9
1.4
2.6
2.6
25
31.5
31.5
10.2
12.9
12.9
19
20
20
-
-
-
160
160
160
16
16
16
R1"
R1"
R1"
 Fig. 2, page 60
About the product
W 200-5 P
W 200-5 P
W 200-5 EP
A
B
C
1660
1625
1625
1880
1880
1880
R1"
R1"
R1"
R1"
R1"
R1"
R¾ "
R¾ "
R¾ "
19
19
19
88
84
84
288
284
284
196
196
196
271
271
271
317
317
317
1.0
1.4
1.5
20
20
20
95
95
95
10
10
10
7.8
7.8
7.8
10
10
10
6.0
6.0
6.0
0.9
0.9
0.9
4.2
4.2
4.2
31.5
31.5
31.5
12.9
12.9
12.9
25
25
25
-
-
6
160
160
160
16
16
16
R1"
R1"
R1"
33

Publicité