Start-up
You have received a completely assembled lifting magnet and detailed operating manual. Please check the condition
of the goods upon receipt for any damage incurred during transport, and make sure the delivery is complete. If you
have any problems, please contact the authorized reseller or manufacturer immediately.
Be sure to read the operation instructions completely before using this magnet for the first
time!
1. Follow the safety instructions. Clean the work piece and the magnetic contact area of the lifting magnet.
Note: Although the activation lever of the TML-Magnet is facing upwards (OFF position), the magnet
still has a slight magnetic pre-tensioning. This pre-tension does not only allow for ease of positioning
the TML 500 F to the workpiece, it also avoids inadvertent slippage or dropping of the lifting magnet
or the workpiece.
2. Position the lifting magnet at the center of gravity of the load.
3. Align the lifting magnet according to the desired application. Always ensure a vertical load direction of the
eyebolt.
4. Press the activation lever down until it is fully engaged in the ON position. Make sure that it is securely
locked underneath the safety tab.
5. Perform a test lift: Move the load hook to the required position and lift the load by about 10 mm to check its
deformation and the magnetic holding force of the TML-Magnet.
6. Check for any air gap developing at the edges of the magnetic surface contact area, for instance by means
of a sheet of paper (80g/m
bearing capacity of the lifting magnet will be reduced significantly.
Immediately stop the lift if there is any excessive deformation of the workpiece or an air gap.
Use spreader bars with additional magnets to safely lift large or flexible loads.
7. If the magnetic adhesion is sufficient and there is no deformation, you can continue the lift.
8. Be sure to move your load slowly and smoothly. Avoid swinging, jarring or any lateral load of the eyebolt.
9. After the load has been set down completely and safely, you can deactivate the lifting magnet. To do this,
press the safety tab using the heel of your hand and move the lever upwards into the OFF position.
14
2
). If a small distance (air gap) forms between magnet and workpiece, the load-

Publicité