WALL MOUNTING For wall installations a Wall Kit (14 09 02A White / 14 09 03A Brown) can be used.
1. Cut a 152mm diameter hole through the wall and insert the wall sleeve with the larger diameter sleeve on the
room side and cement both ends into position flush with the wall faces. The wall sleeve should be angled
downwards away from the fan to allow any condensation to drain to the outside wall.
2. Fix the outer grille as required, ensuring the louvres are pointing downwards.
3. Remove the Inner Grille [A]. Insert a small bladed screwdriver between the bottom blade of the Inner Grille and
the Outer Bezel [B]. Gently lever the bottom grille blade upwards and away from the Outer Bezel.
4. Remove the Outer Bezel. Remove the two screws retaining the Bezel to the Base Housing [D]. Please note
that the Outer Bezel is also secured into position via the central section and will require a small force to remove
it.
5. Remove the Cable Grommet [C], and push the cable through the grommet including the outer core secondary
insulation. Please ensure the correct cable is used as outlined in Section C WIRING.
6. Slide the Base Housing into the Wall Liner and secure into position by tightening the Quick Clip screws [F] (fig.
2).
7. Ensure the fan blade rotates freely.
8. Select and follow the appropriate wiring diagram in Section B WIRING.
9. Replace the Outer Bezel ensuring the centre section positively clips into the Base Housing by carefully pushing
from the centre.
10. Switch the mains power supply on and check the fan is operating correctly.
B. WIRING.
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM
This product is designed for fixed wiring installations only. Flexible cord should not be used.
2
2
1. 1mm
or 1.5mm
solid/rigid core flat cable should be used.
2. Select and follow the appropriate wiring diagram (fig. 3).
3. Check all connections have been made correctly and ensure all terminal connections are securely fastened.
4. Ensure the integrity of the seal between the cable outer insulation and grommet and replace in the Base
Housing. THERE MUST BE NO GAPS BETWEEN THE GROMMET AND CABLE.
5. Ensure the impeller rotates and is free from obstructions.
C. SERVICING AND MAINTENANCE.
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED
1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build
up of dirt or other deposits.
2. Wipe the inlets and front face with a damp cloth until clean.
The fan has sealed for life bearings, which do not require lubrication.
© Copyright abc 2010
THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE.
FROM THE POWER SUPPLY DURING MAINTENANCE.
3