Télécharger Imprimer la page

Bosch KAD93AIEP Notice De Montage Et D'utilisation page 33

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installing the water hose
Use the supplied connection hose for installation.
Unpack the bag containing installation materials and
1.
take out the two pads.
Install the two pads to the hose nuts.
2.
water filter nut
3.
Manually connect the hose nut to the tap.
3.
Use the spanner to connect the other hose nut to
4.
the water filter nut.
Checking the water connection for leaks
:
Warning – Risk of leaks and water damage!
After turning on the water valve, make sure that
Ø
there is no leakage at all connection points of the
water lines. If there is a leakage, turn off the valve
immediately and tighten the water connector.
The water lines should not be pressed by heavy
Ø
things and should not bend too much.
Place the water hose in loops or coils so that the
Ø
appliance can be moved away from the wall.
After connection, please flush the lines with
Note:
several cups of water before use. Dispense water
according to the instructions for use. This will last
several seconds as there is still air in the lines and
the water tank.
water filter
4.
Electrical connection
:
Warning – Risk of electric shock!
If the length of the mains cable is inadequate, never
use multiple sockets or extension leads. Instead,
please contact Customer service for alternatives.
The appliance must be connected to a permanently
installed socket.
The socket must be near the appliance and also freely
accessible following installation of the appliance.
The appliance complies with protection class I.
Connect the appliance to 220-240 V / 50 Hz alter­
nating current via a correctly installed socket with
protective conductor. The socket must be protected
by a 10 A to 16 A fuse or higher.
For appliances operated in non-European countries,
check whether the indicated voltage and current type
match the values of your electricity supply. The rating
plate is situated in the bottom right-hand side of the
appliance. The mains cable may be replaced by a
technician only.
:
Warning
Never connect the appliance to electronic energy saver
plugs.
Our appliances can be used with mains and sine-
controlled inverters. Mains-controlled inverters are used
for photovoltaic systems which are connected directly
to the national grid. Sine-controlled inverters must be
used for isolated applications (e.g. on ships or in
mountain lodges) which are not connected directly
to the national grid.
en
33

Publicité

loading

Ce manuel est également adapté pour:

Kad serieKad93aidpKad93abepKad93vbfpKad93vbfp/01