WIRING DIAGRAM

(INDOOR UNIT)
NOTE:
COMPONENT IN DASH LINE
IS OPTIONAL OR FIELD WIRING.
FOR ANTI-COLD WIND
FOR ANTI-COLD WIND
ON
ON
ON
ON
ON
ON
SW1
SW1
1 1 2 2
1 1 2 2
1 1 2 2
TEL0
TEL0
24
24
15
15
8 8
FACTORY
FACTORY
SETTING
SETTING
FOR SETTING AUTO-RESTART
FOR SETTING AUTO-RESTART
FOR SETTING AUTO-RESTART
FOR SETTING AUTO-RESTART
ON
ON
SW3
SW3
1 1
MODE
MODE
AUTO-RESTART
AUTO-RESTART NOT AUTO-RESTART
NOT AUTO-RESTART
FACTORY SETTING
FACTORY SETTING
FOR SETTING NETADDRESS
FOR SETTING NETADDRESS
0 0
ON
ON
S1+S2
S1+S2
1 1 2 2
8 8
CODE
CODE
0~F
0~F
0~15
0~15
NETADDRESS
NETADDRESS
Figure 32. Schéma de câblage des unités avec gaines MMDB009S4­*P, MMDB012S4­*P, MMDB018S4­*P et MMDB024S4­*P
Part code TBD WIRING DIAGRAM(INDOOR UNIT)
FOR ANTI-COLD WIND
FOR ANTI-COLD WIND
ON
ON
ON
ON
ON
ON
SW1
SW1
1
1
2
2
2
2
1
1
1
1
TEL0
TEL0
24
24
15
15
8
8
FACTORY
FACTORY
SETTING
SETTING
FOR SETTING AUTO-RESTART
FOR SETTING AUTO-RESTART
FOR SETTING AUTO-RESTART
FOR SETTING AUTO-RESTART
ON
ON
SW3
SW3
1
1
AUTO-RESTART
AUTO-RESTART
NOT AUTO-RESTART
NOT AUTO-RESTART
MODE
MODE
FACTORY SETTING
FACTORY SETTING
ON
ON
ON
ON
ON
ON
SW5
SW5
1
1
2
2
2
2
1
1
1
1
FACTORY
FACTORY
SETTING
SETTING
FOR SETTING POWER(DC MOTOR MODEL ONLY)
FOR SETTING POWER(DC MOTOR MODEL ONLY)
0
0
0
0
ENC1
ENC1
8
8
8
8
CODE
CODE
4
4
5
5
POWER
POWER
53
53
54~71
54~71
ACCORDING TO RELATED MODEL.
ACCORDING TO RELATED MODEL.
FOR SETTING NETADDRESS
FOR SETTING NETADDRESS
0
0
ON
ON
S1+S2
S1+S2
1
1
8
8
CODE
CODE
0~F
0~F
0~15
0~15
NETADDRESS
NETADDRESS
Figure 33. Schéma de câblage des unités avec gaines MMDB036S4­*P et MMDB049S4­*P
3
M
FAN1
DC MOTOR
DRIVER MODLE
ON
ON
1 1 2 2
EEPROM
EEPROM
DEFAULT
DEFAULT
FOR TEMP. COMPENSATION(HEATING)
FOR TEMP. COMPENSATION(HEATING)
ON
ON
ON
ON
SW6
SW6
ON
ON
1 1 2 2
1 1 2 2
1 1
2
6
CODE
CODE
FACTORY
FACTORY
SETTING
SETTING
0 0
ON
ON
0 0
ON
ON
1 1 2 2
8 8
1 1 2 2
8 8
0~F
0~F
0~F
0~F
16~31
16~31
32~47
32~47
NOTE:
ON
ON
COMPONENT IN DASH LINE
IS OPTIONAL OR FIELD WIRING.
2
2
1
1
2
2
EEPROM
EEPROM
DEFAULT
DEFAULT
ON
ON
1
1
FOR TEMP. COMPENSATION(HEATING)
FOR TEMP. COMPENSATION(HEATING)
ON
ON
ON
ON
ON
ON
SW6
SW6
2
2
1
1
2
2
1
1
2
2
2
2
1
1
2
6
CODE
CODE
FACTORY
FACTORY
SETTING
SETTING
0
0
0
0
0
0
0
0
8
8
8
8
8
8
8
8
9
9
7
7
8
8
A
A
72~90
72~90
91~105
91~105
106~140
106~140
141~160
141~160
0
0
0
0
ON
ON
ON
ON
2
2
1
1
2
2
8
8
1
1
2
2
8
8
0~F
0~F
0~F
0~F
16~31
16~31
32~47
32~47
Reactor
RED
RED
CON2
3
CON1
CN15
4
CN1
CN34
INDOOR UNIT
MAIN BOARD
CN40
CN9
ON
ON
ON
ON
4
X
Y
E
1 1 2 2
1 1 2 2
EEPROM
EEPROM
4
DEFAULT
DEFAULT
0 0
ON
ON
To CCM
Comm.Bus
1 1 2 2
8 8
0~F
0~F
48~63
48~63
3
3
FAN1
M
RED
DC MOTOR
CON2
DRIVER MODLE
RED
CN1
CON1
REACTOR
4
3
CN34
CN15
ON
ON
ON
ON
INDOOR UNIT
MAIN BOARD
2
2
1
1
2
2
1
1
EEPROM
EEPROM
4
DEFAULT
DEFAULT
CN20
CN9
CN40
0
0
X
Y
E
S2 S1
4
8
8
B
B
161
161
0
0
ON
ON
To LVM
TO OUTDOOR
Comm. Bus
COMM. BUS
1
1
2
2
8
8
0~F
0~F
48~63
48~63
19
Fan for
Alarm
Remote
Fresh Air
Output
Control
NOTE:
Remove the short connector of J7
when you use the "on-off" function.
ALA RM
ON/OFF
J7
CN43
CN23
CN33
2
CN13
10
DISPLAY
CN10
BOARD
4
CN6
BLACK
WHITE
CN5
CN3
YELLOW(WHITE)
CN2
BLACK
CN1
CN12
RED
YELLOW
YELLOW
Y/G
BLACK
RED
MAGNETIC RIN
( 30MM)
CONTRACTOR
HEATER
POWER SUPPLY
FAN FOR THE
ALARM
REMOTE
FRESH AIR
OUTPUT
CONTROL
NOTE:
Remove the short connector of J7
when you use the "on-off" function.
ALA RM
ON/OFF
J7
CN43
CN33
CN23
2
CN13
10
DISPLAY
CN10
BOARD
4
CN6
BLACK
WHITE
CN5
CN2
BLACK
CN12
CN1
CN1
YELLOW
YELLOW
BLACK
Y/G
RED
CONTRACTOR
HEATER
POWER SUPPLY
PUMP
M
5
TO WIRED
CONTROLLER
T2
INDOOR COIL TEMP. SENSOR
T1
ROOM TEMP. SENSOR
WATER LEVEL SWITCH
Y/G
1
2
3
G
PUMP
M
5
TO WIRED
CONTROLLER
T2
INDOOR COIL TEMP. SENSOR
T1
ROOM TEMP. SENSOR
WATER LEVEL SWITCH
RED
Y/G
L1 L2
MAGNETIC
RING
( 30MM)