InstallatIon
applIanCe handover
Undo the two screws on the panel cover above the terminals
»
and remove the cover. This releases the pivot limiter and you
can then tilt the appliance forwards.
Mark the fixing holes on the wall.
»
Drill the holes and then insert rawl plugs.
»
Secure the appliance to the wall using the screws supplied or
»
other suitable fixing material.
If you have installed the power cable on a finished wall, insert
»
the cable grommet into the circular panel hole on the connection
side. Route the power cable through the cable grommet.
Insert the cap into the opposite circular panel hole, or into
»
both panel holes if you have installed the power cable on an
unfinished wall.
Connect the cable to the free terminals on the appliance.
»
Note!
Ensure that you do not strip too much of the power
cable to prevent any wires from touching the screws.
Pivot the appliance upwards. Refit and secure the panel cover.
»
This protects the connection space and limits the pivoting range
to approx. 30°.
Adjust the tilt angle as appropriate and secure the pivoting
»
mechanism by tightening both screws previously undone.
Note!
Ensure that the appliance does not touch the power
cable after installation and assembly.
11. Appliance handover
Explain the functions of the appliance to the user. Draw special
attention to the safety information. Hand the operating and
installation instructions to the user.
WWW.stIebel-eltron.CoM
260
12. Specification
12.1 Specification
Model
Type
Part number
operating details
Rated output
W
Connection
heating stage 0
heating stage 1
W
heating stage 2
W
heating stage 3
W
Protection class to EN 60335
Protection
dimensions and weights
Dimensions H x W x D
mm
Weight
kg
Pivoting range
Connecting cable
≥ mm²
12.2 Minimum clearances
≥ 400
IW 120
229339
1200
230 V 1/N/PE ~ 50 Hz 230 V 1/N/PE ~ 50 Hz
Appliance off
Appliance off
400
800
1200
1
IP X4
145 x 535 x 85
145 x 535 x 85
1.55
°
30
1.0
≥ 400
IW 120-180 |
IW 180
229340
1800
600
1200
1800
1
IP X4
1.55
30
1.0