8990905
6.
Reconnect the tool to the air supply.
7.
Ensure the air pressure is within the correct range (see Specifications).
8.
Test the tool on a sample workpiece to ensure desired performance
and results.
9.
Holding the handle (B) firmly, press the tool onto your workpiece in the
desired location and hold steady.
10. Push the nailer into the workpiece until the safety contact pin (D) is
depressed.
11.
Gently squeeze the trigger (E) to drive the fastener into the workpiece.
12. Release the trigger, lift the nailer until the safety contact pin is no
longer touching the workpiece and move to the next spot.
•
You can also choose to operate in single fire mode. After releasing
the trigger, do not lift the nailer. Slide the nailer along the
workpiece while keeping the safety contact pin depressed. A
fastener will fire each time the trigger is squeezed.
13. Inspect the workpiece.
a.
If the fastener is driven too deep or too shallow into workpiece,
adjust the air accordingly before continuing.
b.
If results are as desired, continue.
14. Lift the nailer away from the workpiece when done.
15. When finished with the tool, turn off the air compressor, disconnect
the air hose and discharge any residual air remaining in the tool. Put
the tool away in a safe storage area.
CARE & MAINTENANCE
1.
Maintain the tool with care. A tool in good condition is efficient, easier
to control and will have fewer problems.
2.
Inspect the tool components periodically, including the trigger, safety
mechanisms and spring. Repair or replace damaged or worn
components. Only use identical replacement parts when servicing.
3.
Inspect the tool fittings, alignment, hoses and power supply cord
periodically. Have damaged or worn components repaired or replaced
by an authorized technician. Only use identical replacement parts
when servicing.
4.
Follow instructions for lubricating and changing accessories.
8
Pin Air Nailer
For technical questions call 1-800-665-8685
V1.1