Reconnect the negative pole connection cable of the battery to the
negative pole of the battery.
z Standby / Measuring battery voltage
After connecting the mains supply, the device is in standby mode.
The Standby symbol
connected, the battery voltage is displayed on the LED display (voltage
display
). The segments of the status display
10
measured voltage is below 3.8 V or above 15 V, then this means the
battery is not charging. The error message "Err" will be shown briefly
in the display. The device switches to standby.
z 6 V batteries
If a battery is measured in the voltage range 3.7–7.3 V, then you can
only select Program 1.
z 12 V batteries
If a battery is identified as being in the critical voltage range from
7.3–10.5 V, then the device will check whether it is a fully-charged 6 V
battery or a discharged 12 V battery. Press the program selector button
to select a program. The device carries out a test measurement
11
procedure for approx. 90 seconds. The display will show:
If after approx. 90 seconds, the identified value is between 7.3–7.5 V,
then the 12 V is defective. The device switches to standby.
z Revival
If after approx. 90 seconds, the identified value is between 7.5–10.5 V,
then a 12 V battery is present. The charging process starts with pulse
operation for revival of the battery. The voltage display
10.5 V is reached, the device switches to further charging levels. The
revival procedure is identical for all 12 V charging programs.
z Selecting programs
Please note:
If a battery is identified in the voltage range of 3.7–7.3 V, then programs
2–3–4 cannot be selected. The charging process continues automatically.
Depending on the program selected, the charging characteristics for
voltage, time and temperature are monitored. With diagnosis program,
revival mode and trickle charging.