en Installation instructions
18.6 Electrical connection
To protect the device, only remove the device from the
styrofoam shells when you press the device into the
cut-out. Never place the device upright on one side of
the device.
¡ Check the household wiring before connecting the
appliance.
¡ The appliance fulfils the requirements of protection
class I and must only be operated in conjunction
with an earth conductor.
¡ In the permanent electrical installation, a partition
must be provided in the phases in accordance with
the installation regulations.
¡ If
appears on the appliance's display, it has
not been connected correctly. Disconnect the appli-
ance from the mains and check the connection.
Connecting without a pre-installed cable
Only connect the hob in accordance with the connec-
tion diagram.
¡ If required, install the enclosed copper bridges.
¡ For a 3-/2-phase connection (3 N~/2 N~), the
power cable must correspond to type H05 VV-F or a
higher rating.
¡ Use the current load to determine which wire cross-
section you require. A cross-section of < 1.5 mm² is
not permitted.
¡ For a single-phase connection (1 N~), the power
cable H05RR-F3G4 (length 1 m) is available from
customer service.
18.7 Installing the hob
Do not trap the power cable and do not route it over
sharp edges.
¡ If the oven is a built-under type, route the cable
along the rear corners of the oven to the mains
socket.
¡ Push the hob in until it locks into place.
18.8 Removing the hob
Disconnect the appliance from the power supply.
1.
Push out the hob from below.