Wrist Pulse Oximeter
systems. However, because of the proliferation of radio-frequency transmitting equipment and other sources of electrical noise
in healthcare and other environments, it is possible that high levels of such interference due to close proximity or strength of a
source might disrupt the performance of this device.
12. This equipment is not intended for use during patient transport outside the healthcare facility
13. Portable and mobile RF communications equipment can affect medical electrical equipment.
14. This equipment should not be used adjacent to or stacked with other equipment.
15. Products contain small parts; Keep the equipment away from children and pets.
Rx only: "Caution: Federal law restricts this device to sale by or on the order of a physician."
Cautions:
1. The Wrist Pulse Oximeter must be able to measure the pulse properly to obtain an accurate SpO
measurement. Verify that
2
nothing is hindering the pulse measurement before relying on the SpO
measurement.
2
2. Worn-out data cables may also cause inaccurate data, so if the data is used as a reference to treat a patient, pay special
attention to data cable and check it more frequently.
3. Do not tangle the SpO
cable with the wires of ES (Electrosurgery) equipment.
2
4. Single use accessories should never be reused.
5. Only use SpO
sensors specified by the manufacturer. Other SpO
sensors may cause improper performance.
2
2
6. Optical cross talk can occur when two or more sensors are located in adjoining areas. It can be eliminated by covering each
site with opaque material. Optical cross talk may adversely affect the accuracy of the SpO2 readings.
7. When connecting this device to other peripherals, make sure that you are qualified to operate this device. Any peripheral must
be certified according to the protocol of IEC 60950 or IEC 60601-1. Any input/output device should follow the protocol of IEC
60601-1.
Notes:
1. For routine equipment maintenance, please refer to the service procedures at the associated section as indicated in the
manual.
2. As to the other concerns for attention, please carefully look through the specific chapter in this instruction.
3. The patient is an intended operator. All functions of the device that the patient can safely use.
3