Specifications · Error messages and their meanings
Error messages and their meanings
DC input voltage below 11 V or exceeds 15 V
Err.1
(DC mode )
Err.2
Bad contact. Check the charging wires and retry.
Err.3
Reversed polarity of the battery. Check and retry.
No battery connected or disconnected during
Err.4
charge.
Charger error. Disconnect the battery, remove the
Err.5
charger from the power supply.
Calibration error of the charger. Disconnect and
Err.6
retry.
Die Spannung des angeschlossenen
Akkus ist niedriger/höher als am Ladegerät
Err.7
eingestellt. Überprüfen Sie die eingestellte
Zellenzahl.
Err.8
Balance voltage error. Check the balancer connector.
Safety timer has expired. Disconnect the battery and
StOP
retry.
FULL
Batetry fully charged.
Specifications
Input voltage AC
Input voltage DC
Power
Weight approx.
Dimensions approx.
Battery type
Charging current
Max. Battery capacity
Cut-off
Safety timer
Delta-Peak sensivity
Balancer accurancy
X-pert Charger X50
100-240 V AC
11 - 18 V DC
max. 50 W
295 g (without power cord)
135 x 112 x 60 mm
1-15S NiMH (1.2 - 18 V)
1-6S Lithium (3.3 - 25.2 V)
1-10S Pb (2 - 20 V)
0.1 - 5 A
100 - 9999 mAh
NiMH/NiCd: Delta-Peak
Lithium, Pb: CC/CV
180 min. (factory setting)
NiCd: 8 mV, NiMH: 5 mV
5 mV / cell