1.4.2 "Heating priority" option
• This function helps to keep the water temperature constant by checking the water temperature at regular time
intervals (minimum 5 minute cycle every 60 minutes) by filtration pump control. The filtration is kept operating if the
pool temperature is below the temperature requested.
• For the connection, connect the filtration timer to terminals 1 and 2 (dry contact, no polarity, maximum intensity 8A).
1.4.1 "Alarm" option
• This option enables a relay to be connected to the alarm contact to indicate a fault by remote.
• For the connection, connect the cables to terminals 5 and 6 (dry contact, no polarity, maximum intensity 2A).
1.4.3 Remote "on/off" control option
• This option enables the "on/off" button function to be transferred via a switch installed by remote.
• For the connection, remove the shunt between terminals 7-8 and connect the switch cable in place (potential free
contact, no polarity, 220-240V ~ 50Hz).
• Activate the command by pressing
then
• Press
for 3 seconds:
• Select "Yes" with
• Press
to exit.
8
1
1-
2 : power for the filtration pump power contactor coil
: filtration timer
2
: power contactor (tripolar or bipolar) for the filtration system pump motor
: separate cable for the "heating priority" function
: heat pump terminal unit
: fuse
: heat pump terminal unit
: alarm contact relay
: separate connection cable
: fuse
for 5 seconds when the regulation is not on standby:
,
,
, then validate by pressing
: heat pump terminal unit
: remote "on/off" switch
: separate connection cable
:
,