8.1.
Programming the ends of travel
Turn the key and hold it in position until the cover apron reaches the side opposite the axle. Validate the pool
closed position by pressing
Turn the key and hold it in position until the cover apron is round the axle. Validate the pool open position by
pressing
. The leftmost LED goes out.
Turn the key to close the pool. Hold the key in position until the motor stops. Turn the key in the other direction,
giving it a twit. The slat apron rolls up around the axle. The second LED blinks. After twenty seconds, the LED
goes out. Programming is complete.
.
NOTA BENE:
The ends of travel can be lost from memory in the event of a power outage:
While the cover is in motion, either opening or closing.
If the cover is partially open or partially closed.
In that event, simply reprogram the ends of travel as described previously.
9.
Wiring diagram
Light switch
PROTECTION & SÉCURITÉ
until the leftmost LED starts to blink.
Open
Close
Level
22
AC closing/
AC closed
opening
Motor
Motor
Shielding
2021/09 - Indice de révision : B - Code : 34690
AC open