The cables connected to the Aquamat motor must form a loop lower than the motor connectors to prevent
7.
Setting and programming the end of travel
The ends of travel are managed by a printed circuit board. The control panel is used to program the ends of
travel.
7.1.
The printed circuit board
Number 1: Jumper
There are two possible positions for the jumper, the position is selected depending on the motor drive system.
In the case of an AQUAMAT motor, the jumper connects
Number 2: Dipswitch
Dipswitch number 1 is used to change the direction of rotation of the motor, this will
depend on the side of the pool on which the motor is located (refer to the figure opposite):
‐ Motor on the right-hand side: dipswitch 1 should be set to OFF
‐ Motor on the left-hand site: dipswitch 1 should be set to ON
Dipswitch number 2 should always be set to ON.
Number 3: Fuse
The board should never be fitted with a fuse with a rating above 20 A. The use of a fuse
rated for the automatic cover motor is highly recommended.
In the case of an AQUAMAT motor,
circuit board.
Number 4: Reset
This is used to reset the printed circuit board.
PROTECTION & SÉCURITÉ
CAUTION
the ingress of water.
the left-hand side pin and the central
mount the 10 A fuse (provided) on the printed
20
pin.
Motor on RH side
Motor on RH side