User interface
Problem
Possible faults
Green LED flashes.
Low battery voltage.
Red LED flashes.
Overload.
Temperature deviation.
The power trigger and the start button are
pushed at the same time.
Green LED and red
Battery is empty.
LED flash alternately
Battery is damaged.
Battery charger
LED on the battery
Cause
charger
The green LED is
The battery is not correctly instal-
on and the red LED
led in the battery charger.
flashes.
The battery connectors are dirty.
The ambient temperature is too
high or too low.
The battery is defective.
The green LED and
The battery charger is not cor-
the red LED are off.
rectly connected to the mains
outlet.
Faulty mains outlet.
The battery charger cable is de-
fective.
The battery charger is defective.
Other errors.
If other errors occur, make sure that the product is off, remove the battery and speak to an
approved service agent.
1888 - 005 - 15.12.2023
Troubleshooting
Possible solution
Charge the battery.
The cutting attachment cannot move freely.
Release the cutting attachment.
Let the product become cool.
Release the power trigger and push the start
button.
Charge the battery.
Speak to your service dealer.
Solution
Remove the battery from the charger and install the bat-
tery in the battery charger again.
Clean the battery connectors.
Use the battery charger in temperatures between 0 °C –
+35 °C.
Replace the battery.
Connect the battery charger to a mains outlet.
Connect the battery charger to the voltage and frequency
that is specified on the rating plate.
Speak to an approved service agent.