! IMPORTANT
To clean the combustion chamber, proceed as follows:
Removing the flame trap:
To remove the ash remains from the top of the combustion chamber, the flame trap has to be removed.
To remove the flame trap, lift it up from its seat and rotate it.
Cleaning the tube heat exchanger:
During operation, dust and soot are deposited on the surface of the heat exchanger tubes. To ensure smooth operation throughout
the season, it is advisable to periodically clean the heat exchanger when the stove is cold. Using the cold handle, extract the
scraper rod and firmly move the scraper back and forth.
STORAGE AND DISPOSAL
Use and maintenance manual
This operation must be carried out by a Ravelli Assistance Centre.
Schedule this type of cleaning with the Ravelli Assistance Centre.
HR 160 SNELLA PLUS
Rev.1 26/03/2018
Page 77
EN