Troubleshooting (cont.)
Symptoms
12. Noisy operation.
13. Remote control does not
work.
Effervescence Ports
Symptoms
1. Effervescence ports do not
work.
2. Effervescence ports do not
bubble.
Chromatherapy Lights
Symptoms
1. Chromatherapy lights do
not work.
1023234-5-C
All manuals and user guides at all-guides.com
Probable Causes
B. Heater is turned off on user
keypad.
C. Wiring from heater to control is
loose, disconnected or damaged.
D. Heater does not work.
E. Control does not work.
A. Pump banding straps have not
been cut.
B. Dry or dislodged jet O-ring
(squeal).
A. Batteries improperly installed or
dead.
B. Antenna on wiring harness is
damaged.
C. Remote control not
programmed correctly.
D. Remote control does not work.
E. Control does not work.
Probable Causes
A. Whirlpool pump is not
operating.
B. Butterfly valve does not work.
C. Pump does not work.
D. Control does not work.
A. Air intake on suction line is
blocked.
B. Water flow is too low.
Probable Causes
A. Loose, disconnected or damaged
wiring/connections.
B. Control does not work.
10
Recommended Action
B. Turn heater on.
C. Check wiring for proper
connections.
D. Replace heater.
E. Replace control.
A. Cut pump banding straps with tin
snips.
B. Remove jet, replace and lubricate
O-ring, and reinstall jet.
A. Replace batteries.
B. Replace wiring harness.
C. See homeowners guide or service
manual.
D. Replace remote control.
E. Replace control.
Recommended Action
A. Turn on pump.
B. Replace butterfly valve.
C. Refer to the service manual to
troubleshoot the system. Refer to
installer/dealer.
D. Replace control.
A. Remove blockage.
B. Increase water flow.
Recommended Action
A. Check wiring for proper
connections. Replace wiring if
necessary.
B. Replace control.
Kohler Co.