TROUBLE SHOOTING
Types of Problems
Indication
Charger does not
No Indicator
lights on
work?
Charger has
Fault RED
LED is ON.
no DC output?
No Charging
Fault RED
Current?
LED is
Flashing
Long charging
time, Full light
Fault RED
LED is
does not come
on?
Flashing
MAINTENANCE
 The charger is maintenance free. If the power cord is damaged, the charger must be left to the
reseller for maintenance. The case should be cleaned occasionally. The charger should be
disconnected from the power while cleaning.
Possible Causes
- No AC power
- Output is short circuited
- Reverse polarity connection to
Battery
- Battery is severely sulphated
- Battery has a damaged cell
- Overheat protection mode
- Battery capacity too large
- Battery is defective
Suggested Solution
- Check AC connections and
make
sure Power Point is switched
ON
- Check DC connection
between charger and battery
and make sure they are not
short circuiting.
- Check that the crocodile clips
haven't fallen off the battery.
- Check that the crocodile clips
/ ring terminals are connected
to the correct polarity.
- Check the Battery condition,
age etc.
- Battery may need
replacement.
- Move battery & Charger to
cooler environment
- Check the charger
specification matches the
battery capacity.
- Battery cannot be charged and
must be replaced.