3. ENCODING PANELS
Whenever there is more than one panel, you must program the number of panels.
For more details see the cityline panel´s manual cod. 97758 at
4. CAMERA FOCUS / LOCK RELEASE ACTIVATION TIME
To adjust the camera image or adjsut the lock-release activation time, see Voice assisted
confi guration in button panels cod. 97765. Instructions included with this equipment.
TECHNICAL FEATURES
PANEL TECHNICAL CHARACTERISTICS
Power Supply
Standby Consumption
Audio active consumption
Audio Power in Residence - Entry Panel Direction
Audio Power in Entry Panel - Residence Direction
Operating temperature
Volume can be Regulated in Both Directions.
Notice: The time it takes the amplifi er to be operative upon being powered up is about 60 seconds. During start-up you
can not operate the panel.
PANEL VALUES
Lock-release activation time
Exit button activation time
Panel type
Panel number 0..9 (by default: 00)
- MASTER panel: not active.
MONITOR TECHNICAL CHARACTERISTICS(OSD TFT 4,3" Screen)
Power supply 18 Vdc
Standby consumption
Audio + video consumption
Operating temperature
FLOOR
SECTIONS-DISTANCES TABLE
Distance section table - VIDEO KIT INSTALLATION WITH FILTER (1 AND 2 LINES)
SECTION
CABLE
TERMINALS
per home
without additional
power source
- (i) For the 12Vdc lock-release and max. consumption 250mA, powered by the amplifi er.
4
DUOX VIDEO CITYLINE 1-2 L KIT
01...99 sec. (Default: 03)
00...99 sec. (Default: 06) / (deactivated: 00)
sub-block/block/general entrance. (Default: block)
25 mA
230 mA
[-5º , +40ºC] / [-13º, 131ºF]
Maximum distance (A)
Source/Filter up to Panel
(Panel-Lock release) (i)
www.fermax.es).
18 Vdc
240mA
560mA
2 W
0.15 W
[-25º , +55ºC] / [-13º, 131ºF]
Maximum distance (A)
Source/Filter up to Panel
(WITHOUT lock release)
Maximum distance (B)
Source/Filter up to
Panel
Furthest terminal