Re-adjustment of end limits and modification of the rotation direction (in user mode
8.1- Re-adjustment of UP end limit (mounting B and D only):
1
1- Move the motor to the UP end limit previously adjusted in §4.3 with the UP key.
2- Press simultaneously for 5 seconds the UP and DOWN keys. The motor will run for 0,5 second in one direction and then in
the other direction.
3- Adjust the new position with the UP and DOWN keys.
4- Confirm the new position by pressing 2 seconds the STOP key. The motor will run for 0,5 second in one direction and then
in the other direction. The new end limit is memorized.
8.2- Re-adjustment of DOWN end limit (mounting C and D only):
1
1- Move the motor to the DOWN end limit previously adjusted in §4.3 with the DOWN key.
2- Press simultaneously for 5 secondes the UP and DOWN keys, The motor will run for 0,5 second in one direction and then
in the other direction.
3- Adjust the new position with the UP and DOWN keys.
4- Confirm the new position by pressing 2 seconds the STOP key. The motor will run for 0,5 second in one direction and then
in the other direction. The new end limit is memorized.
The re-adjustment of end limits is automatic every 56 cycles (during 4 cycles) or after a power supply failure for the
following installation : Up end limit, mounting A and C, Down end limit, mounting A and B.
8.3- Modification of the rotation direction (in user mode):
1
5s
9
Cancelling programming
9.1
1- Switch off the power supply to the receiver for 2 seconds.
2- Switch the power to the receiver back on for 7 seconds.
3- Switch off the power supply to the receiver for 2 seconds.
3- Switch the power to the receiver back on.
- If the motor is on the end limit position (up or down), the motor will run
briefly in one direction and then in the other, otherwise, the motor runs for
5 seconds in random direction. The motor is now in the "cancelling"
mode.
If you switch off the power to several motors, they will all be in cancelling mode. That is why, you must "eject" out of this mode
all the receivers that are not to be deprogrammed by sending a command from their individual control transmitter (UP or Down).
9.2- Then, confirm the cancelling of the concerned motor from the individual control:
- Press the "PROG" key of the transmitter more than 7 seconds. Maintain the pressure
until the motor will first run for 0,5 second in one direction and then in the other,
and a few second later, it will run again in both direction. The EHz motor is now as
it was originally configured, and no transmitter and no settings is saved in its
memory and is ready for a new programming.
4/4
All manuals and user guides at all-guides.com
2
2
Do not move the roller shutter to the up or down end limit position.
1 - Press the Up and Down buttons simultaneously for 5 seconds. The motor runs briefly
in one direction, then in the other.
2 - Within 2 seconds, press the Stop button for 2 seconds. The motor briefly runs in one
2s
direction, then in the other. The rotation direction has been changed.
2s
2
5s
5s
8.1
3
4
3
OFF
ON
OFF
2s
8.2
7s
8.3
2s
7s
2s
PROG
4
2s
4
2s
ON
8.4
5s
7s