PW15A... Single point load cells
3
Specifications
Type
1)
Accuracy class
Max. number of load cell interv. (n
Maximum capacity (E
Min. LC verific. interval (v
(Accuracy class C3)
Temperature effect
on zero balance (TK
(Accuracy class C3)
Min. LC verific. interval (v
(Accuracy class C3MR)
Temperature effect
on zero balance (TK
(Accuracy class C3MR)
Maximum platform size
Sensitivity (C
)
n
Zero balance
Temperature effect
on sensitivity (TK
)
C
Temperature range:
+20 ... +40°C [+68 ... +104°F]
−10 ... +20°C [+14 ... +68°F]
Hysteresis error (d
hy
3)
Non linearity (d
)
lin
Min. dead load output return (DR)
Off center load error
Input resistance (R
Output resistance (R
Reference excit. voltage (U
Nom. range of excitat. voltage (B
Max. excitation voltage
Insulation resist. (R
Nominal temp. range (B
Service temp. range (B
Storage temp. range (B
1)
According to OIML R60 with P
2)
Max. eccentric load according to OIML R76
3)
The data for Non linearity (d
typical values. The sum of these data meets the requirements according to OIML R60.
4)
According to OIML R76
A2434-2.1 en/de/fr
)
LC
2)
)
kg
max
)
min
g
),
% of
0
C
n
10 K
),
min
g
),
% of
0
C
n
10 K
mm
mV/V
3)
% of
C
n
10 K
3)
)
% of
C
4)
)
LC
Ω
)
0
)
ref
)
V
U
) with 100 V
GΩ
is
DC
)
T
°C [°F]
)
tu
)
tl
= 0.7
LC
), Hysteresis error (d
lin
7.5
15
20
1
2
5
/
0.5
1
2
/
2.0 "0.2 (Aligned output, suitable for
connection in parallel: 2.0 "0.1 %)
/
n
359 "5 (Aligned output, suitable for connection
in parallel: 359 "0.3 Ω)
−10 ... +40 [+14 ... +104°F]
−10 ... +50 [+14 ... +122°F]
−25 ... +70 [−13 ... +158°F]
) and Temperature effect on sensitivity (TK
hy
PW15A...
C3, C3MR
3000
30
50
75
100 150 200
5
10
10
20
2
5
5
10
500 x 400
0 "0.1
"0.0175
"0.0117
"0.0166
"0.0166
"0.0166
"0.0233
380 "15
5
1 ... 12
15
> 1
) are
C
11
20
50
10
20
HBM