Flush Mount Deflector Kit FMK30D1
(sold separately) is required to flush mount.
Kit FMK30D1 Parts:
Qty.
PART NUMBER
PREF-B020MRP0
Flush Mount
1
Deflector Vent
LX-CZB055MRE0
2
Mounting screws
1. Prepare cabinet opening as shown in Figures 10, 11A and 11B.
2. Position deflector vent and mark holes as shown
in Figures 12A and 12B. Pre-drill using a 1/16" bit.
3. Follow Drawer Installation Instructions on page 13.
Suggested electrical
outlet location*
E
G
J
30" DRAWER MICROWAVE FLUSH MOUNT
B
D
I
H
Figure 10: 30" Drawer Microwave Flush Mount Cutout
KEY
A
6" (152.40 mm) Anti-Tip block width
B
5" (127 mm) electrical outlet opening height
C
3-1/2" (88.90 mm) Anti-Tip block depth
D
4" (101.60 mm) electrical outlet opening width
E
30-5/16" (769.92 mm) minimum
30-5/8" (777.87 mm) maximum flush opening width
F
14-13/16" (376.24 mm)
to bottom of Anti-Tip block
G
Allow 1-1/16" (26.97 mm) overlap
H
23-1/2" (596.90 mm) opening minimum depth
I
22-1/8" (561.97 mm) mounting cleat opening width
J
1-3/4" (44.45 mm) shelf face to cabinet face
K
16-7/8" (428.62 mm) opening minimum height
A
Anti-Tip block
C
F
K
Floor must
support 100 lb
(45.4 kg)
12
DESCRIPTION
Note: Key refers to Figure 10 below.
Note: the face of the shelf must
sit 1-3/4" (44.45 mm) back from
the face of the cabinet.
shelf face
J
cabinet face
E