Remove the
lower drain
plug
Continuous
drain hose
Drain hose
adaptor
Units with
Pump Only
Drain
hose
adaptor
User Manual
WATER DRAINAGE (cont.)
During heating mode, remove the lower drain plug from the
back of the unit and install the drain connector (5/8" universal
female mender) with 3/4" hose (locally purchased). For models
without drain connector, just attach the drain hose to the
hole. Place the open end of the hose adaptor directly over the
drain area in your basement fl oor.
NOTE
Make sure the hose is secure so there are no leaks. Direct the hose
toward the drain, making sure that there are no kinks that will
impede water fl ow. Place the end of the hose into the drain and
make sure the end of the hose is directed downward to let the
water fl ow smoothly. (See Figs with
Installation not recommended. (See Figs with
continuous drain hose is not used, ensure that the corresponding
drain plug and knob are installed fi rmly to prevent leakage.
Drain hose
adaptor
Press the power
cord buckle into
the rear cover.
When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times. The digital
display shows "P1." At this time the air conditioning/
dehumidifi cation process will immediately stop. However, the
fan motor will continue to operate (this is normal). Carefully
move the unit to a drain location, remove the bottom drain
plug and let the water drain away. Reinstall the bottom drain
plug and restart the machine until the "P1" symbol disappears.
If the error repeats, call for service.
NOTE
Be sure to reinstall the bottom drain plug fi rmly to prevent
leakage before using the unit.
).