Replace the Cartridge of Your Kinetico
Filtration System:
Specifications
Description
SMF IC600
SMF IC614
Min / Max Pressure : 30-100 psi
Min / Max Temperature: 40-100˚ F
Inlet / Outlet Size: 3/4" NPT
Systems Tested and Certified by NSF International against NSF/ANSI
Standard 42 and 53 for the reduction of Chlorine taste and odor,
Particulate Class 1, and cyst.
Part Number
16645
16646
Step One
Turn off water feeding the equipment and ensure water-
consuming equipment is either turned OFF or unplugged.
Shut off inlet valve. Push "Red" pressure relief button
located at left end of SMF filter system to relieve pressure
until no more water comes out. Grasp filter cartridge, turn
counter-clockwise 1/4 turn (when viewed from bottom) and
pull downward about 1 1/2" to remove the filter cartridge.
Properly dispose of old cartridge.
Step Two
Remove and discard the sanitary cap from the top of the new
cartridge. Be sure to apply sufficient lubrication (supplied) to
the O-Rings. Align ear on cartridge with notch in filter head
and push upwards to insert. Be sure to push cartridge all the
way in! Turn cartridge clockwise (when viewed from bottom)
until a definite stop is felt and cartridge is sealed. Hand tight
is sufficient. Turn on inlet valve. Flush for 15 minute.
It is recommended that the cartridge be changed at least
yearly, when pressure drops significantly, or when bad tastes
and/or odors return.
Lubricate O-Rings
Kinetico SMF Series Water Filtration System
Service Cycle (gallons)
Chlorine - 50,000 (gal)
Chlorine - 75,000 (gal)
13
Flow Rate (gpm)
5 (gpm)
7 (gpm)