• Do not use the tool in explosive atmospheres.
• Keep the tool at a safe distance from fire or other sources of heat.
Dust and fume hazard
• Dust and fumes generated when using the tool can be harmful to health.
• Direct the exhaust so as to minimize disturbance of dust in a dust-filled environment.
• The operator should make use of appropriate accessories to collect dust and extract fumes.
• Use respiratory protection to protect yourself from dust and fumes.
Noise hazard
• Unprotected exposure to high noise levels can cause permanent hearing loss and other problems, such as tinnitus.
• Wear hearing protection while operating the tool.
• If the tool can be fitted with a silencer, ensure that it is in good condition and installed correctly.
• Operate and maintain the tool as recommended to prevent an unnecessary increase in noise levels.
Vibration hazard
• Exposure to vibration can cause damage to the nerves and blood supply of the hands and arms.
• Keep the hands away from intensely vibrating parts.
• Wear warm clothing when working in cold conditions and keep you hands warm and dry.
• If you experience numbness, tingling, pain or whitening of the skin in your fingers or hands, stop using the tool, inform your employer and consult a physician.
• Operate and maintain the tool as recommended to prevent an unnecessary increase in vibration levels.
• Do not use worn or ill-fitting sockets or extensions, as this is likely to cause a substantial increase in vibration levels.
• Support the weight of the tool in a stand, tensioner or balancer, if possible.
• Do not hold the tool too tightly to minimize the adverse health effects of vibration.
Additional safety instructions for pneumatic tools
• Air under pressure can cause severe injury. Always shut off the air supply, drain the hose of air pressure and disconnect the tool from the air supply when not
in use, before changing accessories or when performing maintenance or repair work.
• Never direct air at yourself or anyone else.
• Always check for damaged or loose hoses and fittings.
• Cold air must be directed away from the hands.
• Do not exceed the maximum air pressure stated on the tool.
• Never carry the tool by the hose.
AIR SUPPLY (FIG. 1)
• You will require an air pressure of 90 psi, and an air flow according to specification.
• Warning: Ensure the air supply is clean and does not exceed 90 psi while operating the tool. Too high an air pressure and unclean air will shorten the product
life due to excessive wear, and may be dangerous, causing damage to property or personal injury.
• Drain the air tank daily. Water in the air line will damage the tool.
• Clean the air inlet filter weekly.
• Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The hose diameter should be 3/8" I.D (internal diameter).
• Keep the hose away from sources of heat, oil and sharp edges. Check the hose for signs of wear and damage and make sure that all connections are secure.
Lubrication
• The use of an automatic filter-regulator-lubricator is recommended as it lengthens tool life and keeps the tool in sustained operation. The lubricator should
be regularly checked and filled with air tool oil.
• Proper adjustment of the lubricator is performed by placing a sheet of paper next to the exhaust ports and holding the throttle open for approximately 30
seconds. The lubricator is properly set when a light stain of oil collects on the paper. Excessive amounts of oil should be avoided.
• It is most important that the tool be properly lubricated by keeping the lubricator filled and correctly adjusted. Without proper lubrication the tool will not
work properly and parts will wear prematurely.
Quick connector
Tool
Quick coupler
Air hose
WWW.NIKOLAOUTOOLS.GR
Quick
connector
Lubricator
Filter
Quick
coupler
Regulator
(0-8.5 bar)
Fig. 1
Air
compressor
Cut-off
valve