Télécharger Imprimer la page

Electrolux TW SL 6E Notice D'utilisation page 74

Publicité

Les langues disponibles

Les langues disponibles

74 electrolux
permitted ambient temperature
1) 7 kg of cotton, centrifuged at 1000 rpm with reference to EN 61121
MACHINE SETTINGS
Setting
Buzzer per-
1. Turn the programme dial to any programme.
manent on/
2. Push at the same time the Dryness (Trockengrad) and Spin speed (U/Min) but-
off
tons and hold down for approx. 5 seconds.
3. The buzzer is by default always off. You can use the buzzer option to activate or
deactivate sound but the machine does not memorise your selection.
Water hard-
1. Turn the programme dial to any programme.
1)
2. Push at the same time the Dryness (Trockengrad) and Time (Zeiwahl) buttons
ness
and hold down for approx. 5 seconds. The current setting is on the display:
3. Push the Start / Pause button again and again until you set necessary level.
4. To memorise setting push at the same time the Dryness (Trockengrad) and
Time (Zeiwahl) buttons or turn knob to Off (Aus) position
Emptying
1. Turn the programme dial to any programme.
water reser-
2. Push at the same time the Spin speed (U/Min) and Time (Zeiwahl) buttons and
hold down for approx. 5 seconds.
voir
-
The current setting is on the display:
2)
warning off
– warning
– warning
1) Water contains, a appliance quantity of limestone and mineral salts of which quantities vary according to
geographical locations thus varying its conductivity values. Relevant variations of the conductivity of the water
compared to those prefixed by the factory could slightly influence the residual humidity of the laundry at the end of
the cycle. Your dryer allows you to tumble dryer the sensitivity of the drying sensor based on conductivity values of
the water.
2) By default the warning LED is always on at the end of the drying cycle or during the cycle if the water reservoir is
full. When using an external drain for the condensed water warning can be offi
+ 5°C to + 35°C
Implementation
low conductivity <300 μS/cm
medium conductivity 300-600 μS/cm
high >600 μS/cm
icon and
icon and
- warning message is off
- warning message is on

Publicité

loading